Connecting the Cables
●
Outdoor Connection:
Connect a grounding cable between the
Ground terminal of the LTE outdoor CPE and a good ground
connection.
●
Preparing and connecting the cable:
Use only UTP-FTP
4x2x24AWG CAT. 5E outdoor cable from an approved
manufacturer. The cable provides pin-to-pin connection on both
ends.
1.
Prepare the cable:
Use a crimp too for RJ-45 connectors to
prepare the wires. Insert them into the appropriate pins and
use the tool to crimp the connector. Make sure to do the
following:
•
Remove as small a length as possible of the external jacket.
Verify that the external jacket is well inside the sealing
cover when connected to the unit, to ensure good sealing.
•
Pull back the shield drain wire before inserting the cable into
the RJ-45 connector, to ensure a good connection with the
connector’s shield after crimping.
The following figure shows the required wire pair connections.
The color codes used in standard cables supplied by the
manufacturer are as listed in the table.