7.4.6.
Amount of active warnings and readout of the active warning
The "W" instruction advises the Profibus of the amount of active warnings. It functions
analogous to the "D" instruction (readout active error messages) but refers to warnings
rather than error messages.
Inquiry from the master:
0xYY
0x57 („W“)
Number of
active
warning
0x00, 0x00, 0x00, 0x00
1 byte
1 byte
2 bytes
4 bytes
7.4.7. Trigger
action in the SideStep
The ”A“ (Action) instruction is used to trigger an action in the SideStep. Depending on the
action to be triggered, additional parameters may be required.
As long as an action is active, no other action may be triggered. Where this is attempted,
the SideStep will ignore the new action and generate an external diagnostic error with
code 0x40.
Inquiry from the master:
0xYY 0x41
(“A“)
ID
Parameter
1 byte
1 byte
2 bytes
4 bytes
Only one action may be active at a time. If no action is active, the Side-
Step responds as described in the individual actions.
If an action is active, the field bus will create the following response:
Response of the SideStep:
0xYY 0x41
(“A“)
ID
0xFF
Source
Number
1 byte
1 byte
2 bytes
1 byte
1 byte
2 bytes
Source:
Active action was started via the GEMÜ SideStep keypad.
Î
Acknowledge (quit) at the GEMÜ SideStep
0x01
Active action was started via the
e.
sy
-com
interface of the GEMÜ
SideStep.
Î
Close active browser window
0x02
Active action was started via the field bus.
Î
Quit with instruction "Q" or
Î
Select action again and quit
0x03