The washing cycle lasts about 5-10 seconds, the drying period can vary (1min – 8 hours)
*If the unit is very wet inside it could take longer to dry).
*If the machine does not restart after a few hours then call your service representative.
NOTE:
It is normal that the
“WASH”
light is on after the device has completed flushing and
the device is totally quiet. The GENANO 310 continues its normal air cleaning operation
automatically when the drying period is over.
NOTE:
Clean the basin after the washing operations if you want to ensure that there will not
remain any harmful material.
RUNNING OUT OF WASHING LIQUID
The device is unable to perform the automatic washing function, if the container has run
out of water*
The yellow
“FILL WATER”
light is on (See signal lights)
The 310 will continue its normal air cleaning operation even if one automatic wash cycle is
missed due to a lack of washing mixture. However, the device stops the air-cleaning opera-
tion if washing liquid/water is still not added after week to the wash water container.
Fill up the water container according to instructions given in the info sheet. Do not
switch the unit OFF.
The yellow
“FILL WATER”
light will be lit until the water container is filled.
The device turns
ON
only after the filling up of the water container with the washing mixture.
1. Add washing mixture to the water container according to the installation instructions
2. Empty and clean the flush water basin if necessary
3. Shut the bottom basin.
The device automatically starts the normal air cleaning operation after the bottom basin is
closed. The
“FILL WATER”
light turns off and green
OK
light illuminates again.
If the bottom basin is not closed during the operation, the green
“CLOSE BASIN”
light illuminates and the air cleaning operation is turned off automatically.
The device automatically continues normal operation when the bottom basin is closed and
the
“CLOSE BASIN”
light turns off.