RXC-3000
Hardware Installation and User Guide
9000-0000-040 Revision 10
20 of 46
Genave Electronics
Triggering RXC-3000 From an Input
The following items describe input triggering:
(1)
Each of the 8 inputs can start an action script, but only one script per switch.
(2)
The action scripts need to be setup before a switch can be attached to them.
(3)
The name of the action script will appear on the screen as you make your selections.
(4)
The action script begins upon the closure of the switch. If the switch is still closed when
the action is complete, it will not trigger again until the switch is opened and then closed
again.
(5)
Each input has a 150 millisecond debounce. If the switch closure is faster than the
debounce, no actions will start.
Please refer to the Programming Guide 9000-0000-041 for more information