77
User
Manual
GWG Gateway
SMS – SMS Remote Control
SMS remote control feature allows users to execute a short list of predefined commands by sending SMS
messages to the router. GWG-40 v3 with Cinterion PLS8-E can not receive SMS messages.
GWR router series implement following predefined commands:
1.
In order to establish PPP connection, user should send SMS containing following string:
:PPP–CONNECT
After the command is executed, router sends a confirmation SMS with “OK” if the command is
executed without errors or “ERROR” if something went wrong during the execution of the
command.
2.
In order to disconnect the router from PPP, user should send SMS containing following string:
:PPP–DISCONNECT
After the command is executed, router sends a confirmation SMS with “OK” if the command is
executed without errors or “ERROR” if something went wrong during the execution of the
command.
3.
In order to reestablish (reconnect the router) the PPP connection, user should send SMS containing
following string:
:PPP–RECONNECT
After the command is executed, router sends a confirmation SMS with “OK” if the command is
executed without errors or “ERROR” if something went wrong during the execution of the
command.
4.
In order to obtain the current router status, user should send SMS containing following string:
:PPP–STATUS
After the command is executed, router sends one of the following status reports to the user:
–
CONNECTING
–
CONNECTED, WAN_IP: {
WAN IP address or the router
}
–
DISCONNECTING
–
DISCONNECTED
5.
In order to establish PPP connection over the other SIM card, user should send SMS containing
following string:
:SWITCH-SIM
After the command is executed, router sends a confirmation SMS with “OK” if the command is
executed without errors or “ERROR” if something went wrong during the execution of the
command.
6.
In order to restart whole router user should send SMS containing following string:
:REBOOT
After the command is executed, router sends a confirmation SMS with “OK” if the command is
executed without errors or “ERROR” if something went wrong during the execution of the
command.
Remote control configuration page is presented on the following figure. In order to use this feature,
user must enable the SMS remote control and specify the list of SIM card numbers that will be used for SMS
remote control. The SIM card number should be entered in the following format: {Country Code}{Mobile
Operator Prefix}{Phone Number} (for example
+38164111222
). SMS service centre number can be obtained
automatically (option “Use default SMSC is enabled”) or manually by entering number under field “Custom
SMSC”.
As presented in the figure configuration should be performed separately for both SIM cards. After
Summary of Contents for GWG
Page 1: ...GWG Gateway USER MANUAL GWG Document version 1 0 1 Date July 2016 WWW GENEKO RS ...
Page 43: ...43 User Manual GWG Gateway Figure 22 RIP configuration page ...
Page 136: ...136 User Manual GWG Gateway Click OK Figure 125 Policies from trust to untrust zone ...
Page 156: ...156 User Manual GWG Gateway Figure 150 Configuration page for SIM keepalive ...