background image

4 English

Table 1: Suggested tone control settings for various acoustical environments

gives the desired playback level and good resolu-

tion of the volume control.

Setting the tone controls

The frequency response of the Genelec 4010A can 

be adjusted to match the acoustic environment by 

setting the tone control switches on the rear panel. 

The controls are “Treble Tilt” and “Bass Tilt”. An 

acoustic measuring system such as WinMLS or 

comparable is recommended for analyzing the ef-

fects of the adjustments, however, careful listening 

with suitable test recordings can also lead to good 

results if a test system is not available. Table 1 

shows some examples of typical settings in various 

situations. Figure 4 shows the effect of the controls 

on the anechoic response.

Treble Tilt 

The Treble Tilt control (switch 3) attenuates the treble 

response of the loudspeaker at frequencies above 5 

kHz by 2 dB, which can be used for smoothening 

down an excessively bright sounding system.

Bass Tilt

The Bass Tilt control offers three attenuation levels 

for the bass response of the loudspeaker below  

2 kHz, usually necessary when the loudspeakers 

are placed near a wall or other room boundaries. 

The attenuation levels are -2 dB (switch 4 “ON”), -4 

dB (switch 5 “ON”) and -6 dB (both switches “ON”).

Mounting considerations

Align the loudspeakers correctly

Always place the loudspeakers so that their acous-

tic axes (see figure 1) are aimed towards the center 

of the listening area. Only vertical placement is pre-

ferred, as it minimises acoustical cancellation prob-

lems around the crossover frequency.

Minimise reflections

Acoustic reflections from objects close to the 

loudspeakers like walls, cabinets etc. can cause 

unwanted colouration of the sound image. These 

can be minimised by placing the loudspeaker clear 

of reflective surfaces.    

Minimum clearances

Sufficient clearance for cooling of the amplifier and 

functioning of the reflex port must be ensured if 

the loudspeaker is installed in a restricted space 

such as a cabinet or integrated into a wall struc-

ture. The surroundings of the loudspeaker must 

always be open to the listening room with a mini-

mum clearance of 3 centimeters (1

3

/

16

”) behind, 

above and on both sides of the loudspeaker. The 

space adjacent to the amplifier must either be ven-

Loudspeaker Mounting Position

Treble Tilt

Bass Tilt

Flat anechoic response

OFF

OFF

Free standing in a damped room

OFF

OFF

Free standing in a reverberant room

OFF

-2 dB

Near to a wall

OFF

-4 dB

In a corner

OFF

-6 dB

Summary of Contents for 4010AW

Page 1: ...4010A Operating Manual ...

Page 2: ...ws on each pole Push the plug into the connector on the loudspeaker Never connect the 4010A to the loudspeaker outputs of a power amplifier integrated amplifier or receiver When all audio connections are completed connect the loudspeakers to mains with the sup plied mains cables They will switch on automati cally ISSTM Autostart The 4010A is equipped with Intelligent Signal Sens ingTM ISSTM Autost...

Page 3: ...SSER RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR NE PAS EXPOSER À L EAU OU L HUMIDITÉ AUCUN COMPOSANT À AVERTISSEMENT WARNING INSIDE REFER SERVICING TO QUALIFIED PERSONNEL TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ 292 6010W BASS TILT 4 dB BASS TILT 2 dB ISS DISABLE SENSITIVITY 10 dB TREBLE TILT 2 dB 292 4010S ON 292 4010T GND 4010A ACTIVE SPEAKER SYSTEM MAINS INPUT 50 60 Hz 30 W 100 240 V MADE IN FINLA...

Page 4: ...d near a wall or other room boundaries The attenuation levels are 2 dB switch 4 ON 4 dB switch 5 ON and 6 dB both switches ON Mounting considerations Align the loudspeakers correctly Always place the loudspeakers so that their acous tic axes see figure 1 are aimed towards the center of the listening area Only vertical placement is pre ferred as it minimises acoustical cancellation prob lems around...

Page 5: ...is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet Guarantee This product is guaranteed for a period of two years against faults in materials or workmanship Refer to supplier for full sales and guarantee terms Compliance to FCC rules This device complies with part 15 of the FCC Rules Operation is subject to the fol...

Page 6: ...ves show the effect of the Bass Tilt and Treble Tilt controls on the free field response of the 4010A 70 75 80 85 d B r A 40 20k 70 100 200 500 1k 2k 5k 10k Hz Genelec Oy 4010 dBr vs freq Hz 10 Jan 13 65 Figure 5 The upper curve group shows the horizontal directiv ity characteristics of the 4010A measured at 1 m The lower curve shows the system s power re sponse ...

Page 7: ...3 in cone 19 mm 3 4 in metal dome Weight 1 5 kg 3 3 lb Dimensions Height Width Depth 181 mm 71 8 in 121 mm 43 4 in 115 mm 41 2 in CROSSOVER SECTION Input connector 7 kOhm pin 1 pin 2 pin 3 gnd Input level for 100 dB SPL output at 1 m 6 dBu Sensitivity 10 dB off Level control range relative to max output 10 dB Sensitivity 10 dB on Desktop control operating range 0 to 4 dB 200 Hz Crossover frequency...

Page 8: ......