background image

Figure 1. 5041A subwoofer enclosure dimensions

Figure 2. Enclosure mounting bracket dimensions

Figure 3. Aligning and attaching the mounting brackets

Figure 4. Attaching the subwoofer cable

ful not to flatten the vibration isolating rubber 
grommets on the grille frame by overtighten-
ing the screws. 

Insert the grille insert to the grille frame.

Painting the Grille

The grille frame and the grille insert can be 
spray painted to match the wall colour. Paint 
the grille frame and insert separately with a 
thin spray. Do not use brushes or rollers. Be 
careful not to clog the holes on the insert with 
paint.

Connecting the  

RAM3 Amplifier

The RAM3 amplifier is designed to be con-
nected to a line level output of a preamplifier, 
Surround Sound processor or other low level 
source. 

NOTE! Never connect the RAM3 to 

a speaker level output of a power amplifier! 

Before making the connections, check that 
the power on all components is turned off. 

Start by connecting the subwoofer cable to 

the amplifier as described in the "Subwoofer 
Cabling"  section  above.  If  using  multiple 
subwoofers, check that the amplifier’s serial 
number matches that of the subwoofer enclo-
sure which it will power. 

The RAM3 has two 10 kOhm signal input 

connectors: a balanced XLR and an unbal-
anced RCA. For long cable connection lengths 
(>10m or >30ft) a balanced line connection 
is recommended as it offers better immunity 
to external interference. However, the RCA 
connection method usually works as well for 
shorter connection lengths in less electrically 
noisy environments. Do not use both inputs at 
the same time. Your Genelec dealer can pro-
vide you with options for signal cables.

The  RAM3  has  a  provision  for  remote 

controlled  switching  between  “ON”  and 
“STANDBY”  modes.  Poles  3  and  4  on  the 
green connector block provide connection to 
a 12 V remote control trigger.

Space Requirement for the 

RAM3 Amplifier

The  RAM3  amplifier  generates  heat  when 
used  at  full  power.  To  avoid  overheating, 
ensure that there is good airflow around the 
amplifier and no external heat sources close 
to it. We recommend installing the RAM3 into 
a  well  ventilated  equipment  rack  using  its 
dedicated RM2 rack mount kit which allows 
airflow through the ventilation holes of the 
amplifier box. The amplifier must always be 
installed in an upright position, never flat on 
its side.

Figure 5. Installing the grille frame and insert

Summary of Contents for 5041A

Page 1: ...Operating Manual 5041A Genelec 5041A Active In Wall Subwoofer ...

Page 2: ...stallation using the provided mounting brackets that pre vent unwanted vibration transfer from the subwoofer to the wall structure The enclo sure is held in place by rubber springs clear of any fixed part of the wall The woofer protection cover should be left in place until the drywall is installed It provides a cut out template for the drywall installers and protects the bass drivers during all s...

Page 3: ...hat the amplifier s serial number matches that of the subwoofer enclo sure which it will power The RAM3 has two 10 kOhm signal input connectors a balanced XLR and an unbal anced RCA For long cable connection lengths 10m or 30ft a balanced line connection is recommended as it offers better immunity to external interference However the RCA connection method usually works as well for shorter connecti...

Page 4: ...cluttered and there is a space of 100 mm 4 or more behind the amplifier The space behind the amplifier must be well ventilated If the temperature inside the rack is likely to rise close to the maximum ambient tempera ture of 35 C 95 F we recommend install ing ventilation fans to ensure that the thermal protection is not activated prematurely Attach the RAM3 to the RM2 rack mount with two M4 screws...

Page 5: ...UTO START function which automatically turns the amplifier to STANDBY mode if an input signal has not been detected for approximately 30 minutes and back to ON mode when the signal returns The function can be deactivated by turning the AUTO START dip switch to OFF A two colour LED on the amplifier panel indicates the amplifier status green for ON and yellow for STANDBY The amplifier mode can also ...

Page 6: ...ection CONNECTORS system specifications 5041A Free field frequency response 3 dB 35 Hz 95 Hz Maximum short term sine wave SPL output averaged from 40 to 85 Hz measured in half space at 1 meter 105 dB Maximum peak SPL output with random pink noise measured in half space at 1 meter 110 dB Self generated noise level in half space at 1 m on axis A weighted 15 dB Drivers 2 x 165 mm 6 5 Weight Subwoofer...