background image

EC Declaration of Conformity

This  is  to  certify  that  the  Genelec  5041A  Active  In-Wall 
Subwoofer conform to the following standards:
 
Safety:
EN 60065: 2002 + A1:2006 / IEC 60065:2001 7th Edition 
+ A1: 2005
EMC:
EN55013(2001)+A1(2003) 
EN55020(2002)+A1(2003) 
EN61000-3-2(2000)+A2(2005)
EN61000-3-3(1995)+A1(2001)
 
The product herewith complies with the requirements of 
The Low Voltage Directive 2006/95/EC and EMC Directive 
2004/108/EC
 

Signed:
 

Ilpo Martikainen

Position: 

Chairman of the Board

Date: 

25-September-2008

Genelec Document D0079R001 Copyright Genelec Oy 9.2008. All data subject to change without prior notice

www.genelec.com

International enquiries: 
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881

Fax +358 17 812 267

Email genelec@genelec.com

In the U.S. please contact: 
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900

Fax +1 508 652 0909

Email genelec.usa@genelec.com

In Sweden please contact 

Genelec Sverige

Ellipsvägen 10B

P.O. Box 5521, S-141 05 Huddinge

Phone +46 8 449 5220

Fax +46 8 708 7071

Email info@genelec.com

In China please contact: 
Beijing Genelec Audio Co. Ltd.
Jianwai SOHO, Tower 12, Room 2306
39 East 3rd Ring Road
Chaoyang District
Beijing 100022, China
Phone +86 0 5869 7915, Fax +86 10 5869 7914

5041A Operating Manual

AmplIfIer SectIon

connectorS

SyStem SpecIfIcAtIonS

5041A

Free field frequency response (± 3 dB)

35 Hz...95 Hz 

Maximum short term sine wave SPL output 
averaged from 40 to 85 Hz, measured in half 
space at 1 meter

105 dB

Maximum peak SPL output with random pink 
noise, measured in half space at 1 meter

110 dB

Self generated noise level in half space at 1 m 
on axis (A-weighted)

≤ 

15 dB

Drivers

2 x 165 mm (6.5")

Weight

Subwoofer enclosure 
Amplifier

 
15 kg (33 lb) 
1.4 kg (3.1 lb)

Dimensions (see Figure 1) 
 
Subwoofer enclosure  

Height
Width
Depth

Amplifier 

Height 
Width
Depth*

 
*Note that the cable connectors require at 
least 100 mm (4”) of space behind the  
amplifier 

 
 
1170 mm (46

1

/

16

”) 

346 mm (13

5

/

8

”) 

82 mm (3

1

/

4

”) 

 
 
177 mm (6

31

/

32

”) (4U) 

54 mm (2

1

/

8

”) 

260 mm (10

1

/

4

”)

5041A

Amplifier short term output power
(Long term output power is limited by driver 
unit protection circuitry)

125 W

Amplifier system THD at nominal output

≤ 

0.05 %

Mains voltage 

85-132 V or 170-265 V  
according to region

Power consumption (average)

Stand by
Idle
Full output

8.5 VA
11 VA
150 VA

5041A

Input connector XLR female 

pin 1 

 

pin 2 
pin 3 

1, balanced 
gnd
+
-

Input connector RCA female

pin 1 

 

pin 2

1, unbalanced
gnd 
+

LINK OUT connector XLR male

pin 1 
pin 2 
pin 3

1, balanced
gnd
+
-

Input impedance

10 kOhm

LINK OUT gain

0 dB

controlS

5041A

Input sensitivity

+12 to –6 dBu

Phase matching control in 90° steps

From 0 to -270°

Bass Roll-Off control operating range  
in 2 dB steps

From 0 to -6 dB @ 35 Hz

Remote control

Remote controlled 
Standby/On switching by 
12 V trigger

Summary of Contents for 5041A

Page 1: ...Operating Manual 5041A Genelec 5041A Active In Wall Subwoofer ...

Page 2: ...stallation using the provided mounting brackets that pre vent unwanted vibration transfer from the subwoofer to the wall structure The enclo sure is held in place by rubber springs clear of any fixed part of the wall The woofer protection cover should be left in place until the drywall is installed It provides a cut out template for the drywall installers and protects the bass drivers during all s...

Page 3: ...hat the amplifier s serial number matches that of the subwoofer enclo sure which it will power The RAM3 has two 10 kOhm signal input connectors a balanced XLR and an unbal anced RCA For long cable connection lengths 10m or 30ft a balanced line connection is recommended as it offers better immunity to external interference However the RCA connection method usually works as well for shorter connecti...

Page 4: ...cluttered and there is a space of 100 mm 4 or more behind the amplifier The space behind the amplifier must be well ventilated If the temperature inside the rack is likely to rise close to the maximum ambient tempera ture of 35 C 95 F we recommend install ing ventilation fans to ensure that the thermal protection is not activated prematurely Attach the RAM3 to the RM2 rack mount with two M4 screws...

Page 5: ...UTO START function which automatically turns the amplifier to STANDBY mode if an input signal has not been detected for approximately 30 minutes and back to ON mode when the signal returns The function can be deactivated by turning the AUTO START dip switch to OFF A two colour LED on the amplifier panel indicates the amplifier status green for ON and yellow for STANDBY The amplifier mode can also ...

Page 6: ...ection CONNECTORS system specifications 5041A Free field frequency response 3 dB 35 Hz 95 Hz Maximum short term sine wave SPL output averaged from 40 to 85 Hz measured in half space at 1 meter 105 dB Maximum peak SPL output with random pink noise measured in half space at 1 meter 110 dB Self generated noise level in half space at 1 m on axis A weighted 15 dB Drivers 2 x 165 mm 6 5 Weight Subwoofer...