background image

Manual Part No. 0J1332 

Rev. D (12/19/11) 

Printed in China.

GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY 

FOR GP SERIES PORTABLE GENERATORS

For a period of two (2) years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its GP Series generators will be free from defects in materials 

and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac 

or a Generac Authorized Warranty Service Dealer, is found to be defective. Repair or replacement pursuant to this limited warranty shall not renew or extend the original 

warranty period.  Any repaired product shall be warranted for the remaining original warranty period only.  Any equipment that the purchaser/owner claims to be defective 

must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, 

are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser. 

Save your proof-of-purchase receipt. If you do not provide proof of the initial purchase date, the manufacturer’s shipping date of the product will be used to determine the 

warranty period.

WARRANTY SCHEDULE

Consumer applications are warranted for two (2) years. Commercial and Rental applications are warranted for one (1) year or 1000 hours maximum, whichever comes first.

CONSUMER APPLICATION FOR THE UNITED STATES AND CANADA ONLY

YEAR ONE – Limited comprehensive coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):

• Engine- All Components

• Alternator- All Components
YEAR TWO – Limited comprehensive coverage on Part(s) listed (proof of purchase and maintenance is required):

• Engine- All Components

• Alternator- All Components

COMMERCIAL/RENTAL APPLICATION

YEAR ONE – Limited comprehensive coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):

• Engine- All Components

• Alternator- All Components

NOTE:  

For the purpose of this warranty “consumer use” means personal residential household or recreational use by original purchaser. This warranty does not apply to 

units used for Prime Power in place of utility where utility power service is present or where utility power service does not normally exist. Once a generator has experienced 

commercial or rental use, it shall thereafter be considered a non-consumer use generator for the purpose of this warranty.

GUIDELINES:

1.  All warranty repairs, must be performed and/or addressed by an Authorized/Certified Generac Dealer, or branch thereof.

2.  Units that have been resold are not covered under the Generac Warranty, as this Warranty is not transferable.

3.  Use of Non-Generac replacement part(s) will void the warranty in its entirety.

4.  Generac may choose to Repair, Replace or Refund a piece of equipment.

5.   Warranty Labor Rates are based on normal working hours.  Additional costs for overtime, holiday or emergency labor costs for repairs outside of normal business hours 

will be the responsibility of the customer.

6.  Warranty Parts shipment costs are reimbursed at ground shipment rates.  Costs related to requests for expedited shipping will be the responsibility of the customer.

7.  Batteries are warranted by the battery manufacturer.

8.  Verification of required maintenance may be required for warranty coverage.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

1.  Costs of normal maintenance and adjustments.

2.  Failures caused by any contaminated fuels, oils or lack of proper oil levels.

3.  Repairs or diagnostics performed by individuals other than Generac authorized dealers not authorized in writing by Generac.

4.  Failures due, but not limited to, normal wear and tear, accident, misuse, abuse, negligence or improper use. 

5.   As with all mechanical devices, the Generac engines need periodic part(s) service and replacement to perform as designed. This warranty will not cover repair when 

normal use has exhausted the life of a part(s) or engine.

6.   Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earth-quake, windstorm, 

hail, volcanic eruption, water or flood, tornado or hurricane.

7.  Damage related to rodent and/or insect infestation.

8.  Products that are modified or altered in a manner not authorized by Generac in writing.

9.  Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).

10. Failure due to misapplication.

11. Expenses related to “customer instruction” or troubleshooting where no manufacturing defect is found.

12. Rental equipment used while warranty repairs are being performed.

13. Starting batteries, fuses, light bulbs and engine fluids.
THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any implied warranties allowed by law shall be limited in duration to the terms of the express warranty 

provided herein. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. GENERAC’S ONLY LIABILITY 

SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL 

DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You also have other rights from state to state.

GENERAC POWER SYSTEMS, INC.  •  P.O. BOX 8 • Waukesha, WI 53187  •  Ph: (888) GENERAC (436-3722)  •  Fax: (262) 544-4851

To locate the nearest Authorized Dealer visit our website www.generac.com

Part No. 0H8902 

Revision E  (10/11)

Warranty

Summary of Contents for 005974-0

Page 1: ...P Series Portable Generator MODELS 005974 0 005975 0 005976 0 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAV...

Page 2: ...Adding Gasoline 8 2 8 Starting Pull Start Engines 9 2 9 Stopping the Engine 10 2 10 Low Oil Level Shutdown System 10 2 10 1 Sensing Low Oil Level 10 Maintenance 10 3 1 Maintenance Schedule 10 3 2 Prod...

Page 3: ...DOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not avoided could result in death or serious injury Indicates a...

Page 4: ...or while hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be properly connecte...

Page 5: ...2 Article X NATIONAL BUILDING CODE available from the American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK available from the Food and Energy Council 909 Un...

Page 6: ...he Hex Head Bolts then install the Locking Flange Nuts 3 Refer to Figure 1 and install the Handle as shown Slide the long Bolts through the Handle Bracket and Handle then install the Hex Nuts Figure 1...

Page 7: ...e service Every 200 hours the SVC icon on the lower left hand corner of the display will flash The message will flash one hour before and one hour after each 200 hour interval providing a two hour win...

Page 8: ...0 watts 7 2 kW of power at 30 Amps The outlet is protected by two 25 Amp 5 0 5 5kW or two 30 Amp 6 5kW push to reset circuit breakers Figure 6 120 240 VAC 30 Amp Receptacle 2 4 HOW TO USE THE GENERATO...

Page 9: ...rical shock However local codes may vary widely Consult with a local electrician for grounding requirements in the area Proper grounding of the generator will help prevent electrical shock in the even...

Page 10: ...ARTING THE GENERATOR Prior to operating the generator engine oil and gasoline will need to be added as follows 2 7 1 ADDING ENGINE OIL All oil should meet minimum American Petroleum Institute API Serv...

Page 11: ...30 days or longer See the Storage section Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur 2 8 STARTING PULL START ENGINES Never start or stop engine with...

Page 12: ...ey cannot be adequately cleaned Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter 3 2 PRODUCT SPECIFICATIONS 3 2 1 GENERATOR SPECIFICATIONS...

Page 13: ...soft bristle brush may be used to loosen caked on dirt oil etc A vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspec...

Page 14: ...stem parts such as the carburetor fuel hose or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separatio...

Page 15: ...9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel...

Page 16: ...14 Notes...

Page 17: ...15 Notes...

Page 18: ...on as a problem occurs The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warranty service can be arranged by contacting either your selling dealer or a Gene...

Page 19: ...int for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions related part repaired...

Page 20: ...choose to Repair Replace or Refund a piece of equipment 5 Warranty Labor Rates are based on normal working hours Additional costs for overtime holiday or emergency labor costs for repairs outside of n...

Page 21: ...DELOS 005974 0 005975 0 005976 0 2A OS GARANT A LIMITADA PELIGRO HUMOS DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO DISE ADO PARA SER USADO EN APL...

Page 22: ...ar gasolina 28 2 8 Arranque de motores de arranque por tiro 29 2 9 Deteniendo el Motor 30 2 10 Sistema de apagado por bajo nivel de aceite 30 2 10 1 Sensando el nivel de aceite 30 Mantenimiento 30 3 1...

Page 23: ...PELIGRO INDICA UNA SITUACI N PELIGROSA O ACCI N QUE SI NO SE EVITA TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO ADVERTENCIA Indica una situaci n peligrosa o acci n que si no se evita podr a traer co...

Page 24: ...ctrico ni dispositivo mientras est de pie sobre agua con los pies descalzos o con las manos o pies h medos PUEDE HABER UNA DESCARGA EL CTRICA COMO RESULTADO El C digo El ctrico Nacional NEC requiere...

Page 25: ...ATIONAL BUILDING CODE disponible en la American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK disponible en la Food and Energy Council 909 University Avenue Co...

Page 26: ...del soporte del manubrio y del manubrio y luego instale los pernos hexagonales Figura 1 Ensamble de la rueda y el manubrio TUERCA BELLOTA M8 UNIDAD DE MANUBRIO RUEDA X 2 PATA DEL MARCO PATA DE GOMA X...

Page 27: ...ras el icono SVC en la esquina inferior izquierda de la pantalla destellar El mensaje destellar una hora antes y una hora despu s de cada intervalo de 200 horas proporcionando una ventana de dos horas...

Page 28: ...ecept culo de 120 240 VAC 30 Amp Use este recept culo para operar cargas monof sicas de 120 Voltios AC a 60 Hz que requieran hasta 3600 vatios 3 6 Kw de potencia a 30 amperios o 240 VAC 60 hz monof si...

Page 29: ...a de bronce o cobre de tierra electrodo proporciona una protecci n adecuada contra descargas el ctricas Sin embargo los c digos locales pueden variar ampliamente Consulte con un electricista local los...

Page 30: ...ceite de motor y gasolina de esta manera 2 7 1 AGREGAR ACEITE DE MOTOR Todo aceite debe cumplir el est ndar m nimo de la American Petroleum Institute API Service Class SJ SL o superior No use aditivos...

Page 31: ...amiento Nunca use productos limpiadores de motor o carburador en el tanque de combustible ya que puede ocasionar da o permanente 2 8 ARRANQUE DE MOTORES DE RECULE ADVERTENCIA Nunca arranque ni detenga...

Page 32: ...s como contenido en BTUs del combustible altitud condiciones del motor etc La potencia m xima disminuye alrededor del 3 5 por cada 1000 pies sobre el nivel del mar y tambi n disminuir alrededor del 1...

Page 33: ...de drenar el aceite Evite una exposici n prolongada o repetida de la piel con el aceite usado Lave completamente las reas expuestas con jab n Use las siguientes instrucciones para cambiar el aceite lu...

Page 34: ...durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vaciarse antes de almacenarse por 30 d as o m s como sigue Retire toda la gasolina del tanque de combustibl...

Page 35: ...a de combustible demasiado rica 11 V lvula de entrada atascada o cerrada 12 El motor ha perdido compresi n 1 Gire el cierre de combustible a ON 2 Limpie o reemplace el filtro de aire 3 Llene el tanque...

Page 36: ...garant a de Generac tan pronto se presente el problema Las reparaciones de garant a deber n completarse en un tiempo razonable sin exceder los 30 d as El servicio de garant a puede arreglarse contact...

Page 37: ...reemplazo programado la parte ser reparada o reemplazada por Generac de acuerdo a la Subsecci n 4 m s abajo Cualquier parte relacionada a las emisiones as reparada o reemplazada bajo la garant a ECS s...

Page 38: ...ar o reembolsar un equipo 5 Los costos de mano de obra cubiertos por garant a se basan en horas normales de trabajo Costos adicionales por sobretiempos feriados o trabajos de emergencia fuera de horas...

Page 39: ...OD LES 005974 0 005975 0 005976 0 GARANTIE LIMIT E DE 2 ANS 2 ANS GAZ D CHAPPEMENT MORTEL Utiliser UNIQUEMENT L EXT RIEUR loin des fen tres portes et vents L UTILISATION N EST PAS PR VUE POUR LES MOYE...

Page 40: ...essence 46 2 8 D marrage des moteurs d marrage manuel 47 2 9 Arr t du moteur 48 2 10 Syst me d arr t de bas niveau d huile 48 2 10 1 D tection de bas niveau d huile 48 Maintenance 48 3 1 Programme de...

Page 41: ...une situation ou une action dangereuse qui si elle n est pas vit e pourrait entra ner la mort ou des blessures graves ATTENTION Indique une situation ou une action dangereuse qui si elle n est pas vi...

Page 42: ...al exige que le b ti et que les pi ces externes lectriquement conductrices du g n rateur soient correctement reli s une terre approuv e Les codes lectriques locaux peuvent galement exiger la bonne mis...

Page 43: ...bia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS Installation et maintenance des syst mes lectriques de secours pour les fermes disponible aupr s de l Americ...

Page 44: ...rter au Sch ma 1 et installer la poign e comme indiqu Faire glisser les boulons longs travers le support de poign e et la poign e puis installer les crous hexagonaux Sch ma 1 Roue et poign e CROU BORG...

Page 45: ...situ e en bas gauche de l cran clignotera Le message clignotera une heure avant et une heure apr s chaque intervalle de 200 heures laissant une marge de deux heures pour effectuer l entretien Lorsque...

Page 46: ...e 25 A 5 5 5 kW ou deux disjoncteurs de 30 A 6 5 kW Sch ma 6 Prise 120 240 V C A 30 A 2 4 UTILISATION DU G N RATEUR Si des probl mes se pr sentent lors du fonctionnement du g n rateur merci d appeler...

Page 47: ...des fils la borne de mise la terre et une tige en cuivre conduite la terre ou une tige la terre lectrode en laiton fournit une protection appropri e contre les lectrocutions Cependant les codes locau...

Page 48: ...e API Institut am ricain du p trole N utiliser aucun additif sp cial S lectionner le degr de viscosit d huile selon la temp rature d exploitation se reporter galement au tableau Au dessus de 40 F util...

Page 49: ...produit nettoyant pour moteur ou carburateur dans le r servoir d essence tant donn que cela pourrait causer des dommages permanents 2 8 D MARRAGE DES MOTEURS D MARRAGE MANUEL AVERTISSEMENT Ne jamais...

Page 50: ...sance nominale 5 5 5 6 5 kW Puissance de surtension 6 25 6 88 8 kW Tension c a nominale 120 240 Charge c a nominale Courant 240 V 5 5 5 6 5 kW 20 8 22 9 27 1 A Courant 120 V 5 5 5 6 5 kW 41 6 45 8 54...

Page 51: ...au minimum toutes les huit heures de fonctionnement Il est n cessaire de conserver un certain niveau d huile 3 3 5 CHANGEMENT DE L HUILE Changer l huile toutes les 100 heures Changer l huile plus sou...

Page 52: ...iter tout probl me avec le moteur le circuit de carburant doit tre vid avant le stockage du moteur si celui ci est d au moins 30 jours Pour cela Vidanger le r servoir d essence de tout le carburant qu...

Page 53: ...osition ouverte ou ferm e 12 Perte de compression du moteur 1 Mettre la soupape d arr t sur ON Marche 2 Nettoyer ou remplacer le filtre air 3 Remplir le r servoir d essence 4 Vidanger le r servoir d e...

Page 54: ...aine n ayant pas t fabriqu es fournies ou approuv es par Generac Vous tes charg de contacter un d positaire de garantie agr par Generac d s qu un probl me se pr sente Les r parations effectu es dans l...

Page 55: ...ement pr vu elle sera r par e ou remplac e par Generac conform ment au paragraphe 4 qui suit Ces pi ces relatives aux missions r par es ou remplac es dans le cadre de la Garantie du SCE seront garanti...

Page 56: ...ipement 5 Le taux de main d uvre sous garantie est bas sur les heures normales de travail Les autres frais relatifs aux heures suppl mentaires aux vacances ou aux co ts salariaux pour les r parations...

Reviews: