background image

Summary of Contents for 1647-0

Page 1: ... Questions Help is just a moment away I 1 11 Call Generac Generator Helpline 1 800 270 1408 M F 8 5 CT Web www generac portables com or www briggsandstratton com 0 9 Model No 1647 0 8 000 Watt AC Generator Manual No 189065GS Revision 4 08 08 2003 ...

Page 2: ...In the State of California a spark arrester is required by lawJ Section 4442 of the California Public ResourcesCode Other states may havesimilar laws Federal lawsapply on federal lands If you equip the muffler with a spark arrester it must be maintained in effective working order SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safe...

Page 3: ...g a battery Wear protective goggles rubber apron and rubber gloves WARNING WHEN ADDING FUEL Turn generator OFF and let it cool at least 2 minutes before removing gascap Loosen cap slowly to relieve pressure in tanlc Fill fuel tank outdoors DO NOT overfill tank Allow spacefor fuel expansion Keep fuel away from sparks open flames pilot lights heat and other ignitionsources DO NOT light a cigarette o...

Page 4: ...connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator CAUTION Use generator only for intended uses tf you have questions about intended use ask dealer or call 1 800 270 1408 Operate generator only on level surfaces DO NOT expose generator to excessive moisture dust dirt or co...

Page 5: ...rical power for the operation of 120 andlor 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads 1201240 Volt AC 50 Amp Receptacle May be used to supply electrical power for the operation of 1201240Volt AC 50 Amp single phase 60 Hz electrical loads Spark Arrester Muffler 120 240Volt AC 50 Amp Receptacle Air Cleaner Uses a dry type filter element and foam pre cte...

Page 6: ...ver the road use To installyour wheel kit you need the following toot Socket wrench with I 2 or 13mm sockets Neddle nose pliers InstallWheel Kit as follows SeeFigure I I Placegenerator on a hard flat surface 2 Stand at control panel end of generator and gently tilt generator up high enough to place wooden blocks beneath cradle This will allow you to add wheels 3 Slide axle through holes in bracket...

Page 7: ...Set battery onto tray 3 Retainbattery to tray with one battery hold down bracket two J bolts two fiat washers andtwo hex nuts Figure 2 4 Connect red battery cable from engine starter switch to positive terminal on battery with bolt washer and nut Figure 2 5 Connect black battery cable to negative terminal on battery with bolt washer and nut Figure 2 6 Double check all connections to ensure they ar...

Page 8: ...receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain DO NOT handle generator or electrical cords while standing inwater while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator OPERATING THE G EN ERATO R CAUTION See Don t Overload Generator on pag...

Page 9: ...or I Make sure entire muffler side of generator is exposed Note that your generator mayappear different from that shown in Figure 4 2 Ensure a minimum of two feet clearance between open side of box and nearest object 3 Faceexposed end away from wind and elements 4 Enclosure should hold enough heat created by generator to prevent problems _ DANGER Operate generator ONLY outdoors Keep at least 2 fee...

Page 10: ...ps for 240Volts The outlet is protected by a 30 Amp push to reset circuit breaker 120 Volt AC 30 Amp Locking Receptacle Use a NEMA L5 30 plug with this receptacle Connect a 3 wire cord set rated for 125Volt AC loads at 30 Amps to the plug Figure 7 _ire Cord Set NEMA L5 30 Neutral 120V Hot Ground Green Use this receptacle to operate 120VoltAC 60 Hz single phase loads requiring up to 3 600 watts 3 6...

Page 11: ...or power is to sequentially add loadsas follows I With nothingconnected to the generator start the engine as described in this manual 2 Plugin and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat step...

Page 12: ...ean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and causeproblems In addition if water enters generator through cooling air slots some of the water wilt ...

Page 13: ...e before placing the cover on the equipment Engine Storage See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh gasoline Run the unit for several minutes to circulate the additive through the carburetor The unit and fuel can then be stored for up to 24 months ...

Page 14: ... Disconnect shorted electrical Generator runs good at no load load but bogs down when loads are 2 Generator is overloaded 2 See Don t Overload Generator connected 3 Shorted generator circuit 3 Contact Authorized service facility Generator will not start or starts Low oil level Fill crankcase to proper level or place and runs rough generator on level surface I Out of gasoline I Fill fuel tank Gener...

Page 15: ...NOTES I IS ...

Page 16: ...SCHEMATIC 66 77 FUSE 77 lO AHp J 13 _2_ra _ _hYST_ EXCITATION COIL qk CAPACITDR POWER POWER _INDING XINDING _ BLK BLU _i ENG IGNITIDN 8 B IIA I 16 ...

Page 17: ...WIRING DIAGRAM I 17 ...

Page 18: ...g s EXPLODEDVIEW MAIN UNIT 10 5 6 _ TO STARTER 61 _TO TERMINAL ON BAWERY 72 18 25 52 13 55 18 s2_ 55 51 56 77 54 46 57 19 11 26 25 65 mira 18 ...

Page 19: ...NUT Nylok 189065GS 27 187104GS WASHER Nylon MS5375 28 39287GS SCREW MS6497 29 B85586GS HANDLE Includes Item 30 193347GS 30 84605GS GRIP 807948 31 189051GS ASSY Control Panel see page21 807595 32 82153GS SCREW 805812 34 73054GS DECAL Fuel Shut Off 392154 35 87680GS NUT Wing 690661 36 45757GS SCREW 692056 37 49813GS NUT 692359 38 1955362 GS ASSY Wire Ground BB3061GS 39 192980GS KIT Valve Fuel 43438G...

Page 20: ... 4 Item I 2 3 4 5 6 7 8 9 10 II Part 191267JGS B4966GS 191265GS 22247GS 191413GS 22145GS 22413GS 39253GS 22129GS B189085GS 192432GS Description AXLE WHEEL E_RING WASHER VIBE MOUNT with Washer WASHER SCREW SCREW WASHER Lock LEG Support NUT Lock 20 ...

Page 21: ... SCREW 19 75476GS SWITCH 20 92953GS WASHER Lock 21 189127GS OUTLET 50A 240V 22 51714GS BREAKER Circuit 23 186102GS BREAKER Circuit 24 B4893GS BREAKER Circuit 25 BI89104GS OUTLET 20A 120V 26 B4894GS WASHER 27 43181GS OUTLET 30A 120V Locking 28 43182GS OUTLET 30A 120V 240V Locking 29 B4892GS NUT 30 77314GS 17 Description WASHER WASHER Lock SCREW SCREW BLOCK Terminal 50A GROMMET Rubber NUT ASSY Wire ...

Page 22: ...aft Stay 4 B4909GS BOLT Stay 5 B4910GS ASSY Housing 6 187049GS PLUG Domed 7 B4912GS COVER Blind End 8 B4913GS COVER Top Black 9 B4914GS CAPACITOR I I B4916GS CAPACITOR Diode Varistor EMC 12 191297GS ASSY Rotor Includes Item I I 14 B4919GS SCREW 15 B4920GS SCREW 16 49820GS NUT Lock 17 188928GS CONNECTOR 6 Pin Sincro 18 22473GS WASHER 19 49813GS NUT 22 ...

Page 23: ...ON POWER PRODUCTS EQUIPMENT SAVEYOUR PROOF OF PURCHASE RECEIPT IFYOU DO NOT PROVIDE PROOF OFTHE INITIAL PURCHASE DATEATTHETIMEWARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OFTHE EQUIPMENTWILL BE USEDTO DETERMINETHEWARRANTY PERIOD About your equipment warranty We welcome warranty repair and apologize to you for being inconvenienced Any Authorized service dealer may perform warranty repairs M...

Page 24: ...ecci6n 4442 del C6digo de Recursos P_blicos de California Otros estados pueden tener leyes similares Lasleyes _ederalesse aplican en tierras federales Si equipa el silenciador on un apagachispas este deber_ ser mantenido en buenas ondicionesde trabaio INSTRUCCIONES DE SEGURIDAD _k Este es el simbolo de alerta de seguridad Sirve para advertir al usuario de un posible riesgo para su integridad fisic...

Page 25: ...tectoras delantal y guantes de goma ADVERTENCIA CUANDO AI_IADA COMBUSTIBLE Apague el generador posici6n OFF y d6jelo enfriar al menos pot 2 minutos antes de remover la tapa de la gasolina Afloje la tapa lentamente para dejar que la presi6n salgadel tanque Llene el tanque al aire libre NO Ilene demasiado el tanque Permita al menos espacio para la expansi6n del combustible Mantenga la gasolinaalejad...

Page 26: ...en la posici6n de apagado OFF luego encienda ON para su operaci6n Apague OFF las cargasel_ctricas y desconSctelas del generador antes de parar el generador PRECAUCION Use el generador solamente con la finalidad para el cual rue diseffado Si usted tiene algunapregunta acerca de las flnalidades de uso del generador preg6ntele a su concesionario o Ilamada a 1 800 270 1408 Opere el generador solamente...

Page 27: ...motor y est_ equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 7 galones americanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120VoltiosAC 20Amp Pueden ser utilizados para suministrar alimentacibn el6ctrica para Tomacorriente de 120 240 Voltios AC 50 Amperios Silenciador Apagachispas el funcionamiento de cargas del motor herramientas ap...

Page 28: ... Juego de Ruedas usted necesitar_ las siguientes herramientas Dos cajas de 13ram box extremo abierto o Ilave de tubo Unas pinsasde punta Instale el Juego de Ruedas como sigue Figura 10 L Coloque el generador sobre una superficie plana y dura 2 P_rese en el extremo del motor del generador e inclineel generador cuidadosamente haciaadelante Io suficiente como para colocar bloques por debaio del armaz...

Page 29: ...soporte utilizando dos pernos en J dos arandelas planas y dos tuercas hexagonales Figura I I 4 Conecte el cable rojo de la baterta del interruptor de arranque del motor al terminal positivo de la bateria con cerroio la arandela y la tuercas Figura I I 5 Conecte el cable negro de la baterta al terminal negativo de la baterta con cerrojo la arandela y la tuercas Figura l I 6 Revise nuevamente todas ...

Page 30: ... de ualquier forrna NO opere el generador bajo la lluvia NO maneie el generador o cables el_ctricos mientras este parado en agua descalzo o cuando las manos y los pies est_n mojados NO permita que personas descalificadas o nifios operen o sirvan al generador OPERANDO EL GENERADOR PRECAUCION Vea No sobrecargue generador en la p_gina 33 Enciendasu generador y deje clue el motor se estabilice antes d...

Page 31: ...idad puede tener otra apariencia como se muestra en la Figura 13 PELIGRO Opere el gener_dor SOLAMENTE al aire libre Mantenga al menos 2 pies de espacio libre alrededor del generador para la _decuada ventilaci6n NO opere el generador dentro de un ed_cio o lugar cerrado incluyendo el cornpartimiento del generador en un vehiculo recreativo o R_Z Retire la protecci6n cuando la temperatura sea superior...

Page 32: ...corto circuito de 30Amp del tipo empuie para reposicionar Tomacorriente de 120 Voltios AC 30 Amperios Use un enchufe tipo NEMA L5 30 con este tomacorriente Conecte un juego de cordones de 3 alambres de 125Voltios a 30 Amperios AC o de mayor capacidad al enchufe Figura 16 Utilice este tomacorriente para operar cargasde 120Voltios AC 60 Hz monof_sicas que requieran hasta 3 600 vatios 3 6 kW de poten...

Page 33: ...aslas cargas como se describe a continuaci6n I 2 3 Sin tener nada conectado al generador encienda el motor de la manera descrita en este manual Conecte y encienda la primera carga preferiblemente la mayor que usted tenga Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr6xima carga 5 De nue...

Page 34: ...re de enfriamiento del generador no deben estar tapadas con nieve hoias o cualquier otro material extraffos Revise frecuentemente la limpieza del generador y llmpielo cuando est_ con polvo sucio con aceite humedad o cuando otras substancias extraffas sean visibles en su super_cie exterior NOTA NO recomendamos el uso de manguerasde lardln para limpiar el generador El agua podrla introducirse en el ...

Page 35: ...l NO almacene gasolina de una estacibn a otra estacibn al menos que haya sido tratada como se mencionb antes Reemplace la caneca de gasolina si comienza a oxidarse El bxido y o la suciedad en la gasolina le causar_ problemas Almacene la unidad en un _rea limpia y seca DIAGNOSITICOS DE AVERiAS Problemo El motor est funcionando pero no existe salida de AC disponsible Accion I El interruptor autom_ti...

Page 36: ...D NO PROVEE LA PRUEBA DE LA FECHA DE LA COMPRA INICIAL AL HOHENTO EN QUE SE REQUIERA USAR LA GARANT A LA FECHA DE LA FABRICACI_ N DEL EQUIPO SERA USADA PARA DETERHINAR EL PERIODO DE GARANTiA Acerca de la seguridad de suequipo Nosotros reciben las reparaciones baio lagarantta y le pide disculpas por cualquier inconveniencia causada Cualquier Concesionario de Servicio Autorizado puede Ilevar a cabo ...

Reviews: