background image

GENERAC PORTABLE PRODUCTS OWNER EQUIPMENT WARRANTY POLICY

Effective November 1, 2004

WARRANTY PERIOD*

* The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the
period of time stated in the table above. "Consumer use" means personal residential household use by a retail consumer.
"Commercial use" means all other uses, including use for commercial, income producing or rental purposes. Once equipment has
been used commercially, it shall thereafter be considered to be in commercial use for purposes of this warranty.

** The engine and starting batteries are warranted solely by the manufacturers of those products.

WARRANTY REGISTRATION IS NOT NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON POWER
PRODUCTS EQUIPMENT. SAVE YOUR PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE
INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED,THE MANUFACTURING DATE OF THE
EQUIPMENT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.

About your equipment warranty:

We welcome warranty repair and apologize to you for being inconvenienced.Any Authorized service dealer may perform warranty
repairs. Most warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For
example, warranty service would not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping,
handling, warehousing or improper installation. Similarly, the warranty is void if the manufacturing date or the serial number on the
equipment has been removed or the equipment has been altered or modified. During the warranty period, the Authorized service
dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use and service.This
warranty will not cover following repairs and equipment:

Normal Wear: Outdoor power equipment, like all mechanical devices, needs periodic parts, service and replacement to perform
well.This warranty does not cover repair when normal use has exhausted the life of a part or the equipment.

Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or
unauthorized installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper
maintenance, repair or storage so as, in our judgment, to adversely affect its performance and reliability.This warranty also does not
cover normal maintenance such as adjustments, fuel system cleaning and obstruction (due to chemical, dirt, carbon or lime, etc.).

Other Exclusions: Also excluded from this warranty are wear items such as quick couplers, oil gauges, belts, o-rings, filters,
pump packing, etc., pumps which have been run without water supplied or damage or malfunctions resulting from accidents,
abuse, modifications, alterations, or improper servicing or freezing or chemical deterioration. Accessory parts such as guns,
hoses, wands and nozzles are excluded from the product warranty.This warranty excludes failures due to acts of God and other
force majeure events beyond the manufacturers control. Also excluded is used, reconditioned, and demonstration equipment;
equipment used for prime power in place of utility power and equipment used in life support applications.

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON,WISCONSIN, U.S.A.

LIMITED WARRANTY

"Generac Portable Products is a licensed trademark of Briggs & Stratton Power Products. Briggs & Stratton Power Products will
repair or replace, free of charge, any part, or parts of the equipment** that are defective in material or workmanship or both.
Transportation charges on parts submitted for repair or replacement under this warranty must be borne by purchaser.This
warranty is effective for the time periods and subject to the conditions provided for in this policy. For warranty service, find your
nearest Authorized service dealer by calling 1-800-270-1408.Warranty service may only be performed by a Briggs & Stratton
Power Products Authorized service dealer.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND
FITNESS  FOR A  PARTICULAR  PURPOSE, ARE  LIMITED TO THE TIME  PERIOD  SPECIFIED, OR TO THE  EXTENT  PERMITTED
BY LAW. ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR CONSEQUENTIAL DAMAGES UNDER
ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some countries or
states do not allow limitations on how long an implied warranty lasts, and some countries or states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you.This warranty gives
you specific legal rights and you may also have other rights that vary from country to country or state to state.”

PRODUCTS**

CONSUMER USE

COMMERCIAL USE

Pressure Washer

1  year

90  days

Portable Generator

2 years (2nd year parts only)

1 year

Summary of Contents for 4000EXL

Page 1: ... 000 Watt AC Generator Manual No 189189GS Revision 11 03 01 2005 BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Generac Portable Products is a licensed trademark of Briggs Stratton Power Products Before using this product read this manual and follow all Safety Rules and Operating Instructions CAUTION ...

Page 2: ... the engine owner s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety alert symbol is used with a signal word DANGER CAUTION WARNING a pictorial and or a safety message to alert you to hazards DANGER indicates a hazard which if not avoided wil...

Page 3: ...fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT operate generator inside any building or enclosure including the generator compartment of a recreational vehicle RV Running generator gives of...

Page 4: ...arting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on Rapid retraction of starter cord kickback will pull hand and arm toward engine faster than you can let go Broken bones fractures bruises or sprains could result WARNING WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnec...

Page 5: ...motor loads 120 240 Volt AC 20 Amp Receptacle May be used to supply electrical power for the operation of 120 and or 240 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Protects engine by filtering dust and debris out of intake air Choke Lever Used when starting a cold engine Circuit Breakers AC Each receptacle is provided with a push to reset circu...

Page 6: ...negative black battery cable To install 1 Cut off tie wrap securing loose end of negative black cable 2 Connect negative black battery cable to negative terminal on battery Figure 1 3 Verify that connections to battery and generator are correct and secure Install Handle To install the handle you need the following tools 2 13 mm 1 2 box open end or socket wrenches Install handle as follows 1 Remove...

Page 7: ...aded fuel to fuel tank Be careful not to fill above the baffle This allows adequate space for fuel expansion Figure 3 4 Install fuel cap and wipe up any spilled fuel CAUTION Refer to engine manual for oil fill information Damage to equipment resulting from failure to follow this instruction will void warranty Any attempt to crank or start the engine before it has been properly filled with the reco...

Page 8: ...NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Figure 4 Prevailing winds and air currents should be taken into consideration when positioning generator Figure 4 Generator Clear...

Page 9: ...ting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it CAUTION Figure 5 Fuel Shut off Valve Figure 6 Idle Control Switch DO NOT touch hot surfaces Allow equipment to cool be...

Page 10: ...e tight 3 If necessary clean battery terminals 4 Connect battery charge cable connector plug to panel receptacle identified by the words 12 VOLTS D C 5 Connect battery charge cable clamp with red handle to the positive battery terminal Figure 7 6 Connect battery charge cable clamp with black handle to the negative battery terminal Figure 7 7 Start engine Let engine run while battery recharges 8 Wh...

Page 11: ...lt AC 20 Amp Locking Receptacle Use a NEMA L14 20 plug with this receptacle Connect a 4 wire cord set rated for 250 Volts at 20 Amps or greater Figure 10 You can use the same 4 wire cord if you plan to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 2 000 watts of power at 16 7 Amps for 120 Volts 4 000 watts of power 4 0 kW at 16 7 Amps for 240 V...

Page 12: ...ed battery See Charging a Battery on page 10 before attempting to recharge a battery This outlet is protected by a 10 Amp self resetting circuit breaker COLD WEATHER OPERATION Under certain weather conditions temperatures below 40 F 4 C combined with high humidity your generator may experience icing of the carburetor and or the crankcase breather system To reduce this problem you need to perform t...

Page 13: ... to prevent icing problem 10 Start and run engine outdoors 11 Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings 12 DO NOT enclose generator any more than shown in Figure 13 13 Remove shelter when temperatures are above 40 F 4 C 14 Turn engine OFF and let cool two 2 minutes before refueling Figure 13 Permanent Cold Weather Shelter Wind DO NOT...

Page 14: ...rator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattages listed are approximate only Check tool or applia...

Page 15: ...r any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water ...

Page 16: ...more than 30 days use the following guidelines to prepare it for storage Generator Storage Clean the generator as outlined in Generator Cleaning Check that cooling air slots and openings on generator are open and unobstructed Engine Storage See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel system or on essential carburetor parts empty all two supplie...

Page 17: ...1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Generator 3 Contact Authorized service facility Generator will not start or starts and runs rough 1 Fuel Valve is in Off position 2 Failed battery 3 Low oil level 1 Turn fuel valve to On position 2 Replace battery 3 Fill crankcase to proper level or pl...

Page 18: ...18 4000EXL Extended Life Generator NOTES ...

Page 19: ...4000EXL Extended Life Generator 19 NOTES ...

Page 20: ...udgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as adjustments fuel system cleaning and obstruction due to chemical dirt carbon or lime etc Other Exclusions Also excluded from this warranty are wear items such as quick couplers oil gauges belts o rings filters pump packing etc pumps which have been run without water supplied or ...