background image

Menu Options 

Time & Value 

Day of Week 

Scheduled Programs 

 

 

 

 
 

 

 

1.  LCD DISPLAY LAYOUT 

 

 

 

 

 

 

 

2.  SETTING TIME AND DAY OF WEEK 

 

 

3.  MANUAL VENTIALTION MODE  

 

 

 

 

 

 

 

 

 
 

 

 

 

 

4.  MANUAL HEAT MODE 

 
 

 
 

 
 
 
 
 
 
 
 

 

 

5.  SWITCHING BETWEEN SETPOINT 

AND VARIABLE HEAT MODES 

 

 

 

 

 

 

 

 

 

 

 

 

6.  HIGH ELEVATION MODE 

 

When heater is used at elevations between 

1500m  and  4000m  above  sea  level,  heater 
should be operated in 

High Elevation Mode

 to 

make  sure  enough  oxygen  is  provided  for 
efficient combustion of fuel.  

To  toggle 

High  Elevation  Mode

,  press 

[<]

 

and 

Ok

 buttons simultaneously while in heating 

mode. This works in both 

Setpoint

 and 

Variable 

Heat

 modes.

 

It is not recommended using the heater at 

more than 4000m above sea level. 

 

Using 

[<]

 and 

[>]

 keys, navigate 

to 

Clock Icon

 and press 

Ok

.

 

Days of Week

 segment lights up. 

Select current day using  

 

[<]

 and 

[>]

 keys and press 

Ok

.

 

Hours

 segment begins to flash.  

Set hour (military time, 0-23) using  

 [<]

 and 

[>]

 keys and press 

Ok

.

 

Minutes

 segment begins to flash. 

Set minutes using  

 

[<]

 and 

[>]

 keys and press 

Ok

.

 

Day of week and time  

are now set.

 

Timer LCD is comprised 
of several distinct 
segments, such as 
Menu Options, Day of 
Week, Scheduled 
Programs and Time & 
Value field.

 

Using 

[<]

 and 

[>]

 keys, navigate to 

Fan Icon

 and press 

Ok

.

 

Ventilation Mode started

Select fan intensity between 01 

and 07 using 

[<]

 and 

[>]

 keys

 

Press 

Power Button

 to exit 

ventilation mode. 

Fan will ramp down and stop. 

Using 

[<] 

and 

[>]

 keys, navigate to 

Heat Icon

 and press 

Ok

.

 

Heating Mode started

Select heat intensity between 01 

and 07 using 

[<]

 and 

[>]

 keys

 

Please note, it takes approx. 2-3 

minutes for the heater to start 

heating or to come to a full stop.

 

Press 

Power Button

 to exit 

manual heating mode. 

Heater will cool down and stop. 

While  in  heat  mode,  press  and 
hold 

Ok

  button  for  3  seconds  to 

toggle  between 

Variable  Heat

 

and 

Setpoint

 

(thermostatic) 

modes. 

In 

Setpoint  Mode

,  heater  will 

maintain 

preset 

ambient 

temperature  (between  5°C  and 
35°C)  based  on  the  reading  of 
internal  or  external  temperature 
sensors. 

In 

Variable  Heat  Mode

,  heater 

will  continuously  produce  heat 
based  on  the  setting  01  –  07, 
which translates into 0.5Kw – full 
capacity (2, 4 or 5Kw, depending 
on model).

 

QUICK START 

GUIDE

 

GC0653 

DIGITAL TIMER 

FOR AIR HEATERS 

 

Reviews: