Installation
CG-1220 DTR
3-5
the highlight from the fault display on the DTR LCD and restoring the Summary Fault
contact to the normal (no-fault) state, which is CLOSED. However it may not clear
the fault condition. If any new faults occur after the Summary fault relay was
forced to close by using ACKNOWLEDGE FAULTS, the Summary Fault relay will
open again to indicate a new fault condition.
The following listing of faults that can cause a Summary Fault in the DTR (also listed
in Appendix C under the 5.1 Keyword Commands, LIST-FAULTS keyword
description):
Low Input Signal
Input Saturated
MCU Link loss
DSP Link loss
DSP Data loss
SPU Overflow
TBT Link loss
TBT Summary Fault
TBT in Local Ctrl
Out of Band
Invalid Band Setup
Band 1 BDC fault
Band 2 BDC fault
Band 3 BDC fault
Band 4 BDC fault
PLL1 Unlocked
PLL2 Unlocked
Temperature alarm
NVRAM corrupted
Mute Switch Fault
SPU Link locked
3.3.1.1.3
Beacon Select Inputs (GPIO 0-3)
The BEACON SELECT inputs (not available on Monopulse units) are formed through
pin groups (5,18), (6,19), (7,20) and (8,21)—internal drive common ground, short
GPIO + to – to turn off optically coupled isolator. GPIO 0-3 are inputs that switch
the DTR to a pre-set BEACON (set of parameters). The main purpose is to provide
a discrete, parallel control interface that is compatible with existing 7134 (and
7200) controllers. Selecting one of the 4 BEACON inputs, while the DTR is in
REMOTE CONTROL (not Local) and the REMOTE CONTROL PORT parameter is set
to I/O Interface #1, will enable the DTR to switch to the pre-set BEACON
parameters.
To setup the beacons, the appropriate DTR parameters should be set, and the
STORE BEACON command executed. (Refer to Section 3.5.2 for further
information about setting up beacons.) This action will store the BEACON
parameters into NVRAM, which may then be recalled from the CONFIGS/BEACON-
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...