Appendix C– DTR Remote M&C Protocol
CG-6073 (Rev R, Jun, 2012)
32
MANUAL IF OVERRIDE
Path:
/ CONFIGS MEMORY CALIBRATION IF-OVERRIDE
Type:
Sub Menu
Syntax:
IF-OVERRIDE
Notes:
The IF OVERRIDE menu allows the user to manually select the IF used by the L-
Band front end. The DTR normally selects the optimal IF; this menu provides
flexibility for special cases.
MASTER ADDRESS (v 1.19.06 or later)
Path:
/ CONFIGS COMM-PARAM PORT-3 MASTER-ADDRESS
Type:
Data Editor
Syntax:
MASTER-ADDRESS [= n] | [D]
Range:
Integer: 0 .. 31
Notes:
MASTER-ADDRESS is the address of the master (controlling) device on the multi-
drop RS-485 bus. There are a maximum on 32 addresses, ranging from 0 to 31. On
the bus, the actual ASCII value used for addressing is the address assigned here
plus the value of the parameter ADDRESS OFFSET.
MESSAGE LOG
Path:
/ STATUS LOG
Type:
Executable
Syntax:
LOG
Notes:
The MESSAGE LOG displays the most recent events recorded in system’s message
log. The latest message is at bottom of the screen and pressing SHIFT-PAGE scrolls
the list to display previous messages.
MINIMUM REF LVL
Path:
/ CONFIGS OPERATION ANALOG-OUTPUTS DAC1 DAC1-REF
Type:
Data Editor
Syntax:
REFERENCE [= n] | [D]
Range:
Real: -150.0 .. 20.0
Notes:
The MINIMUM REF POWER LVL is the minimum input power level reference which
corresponds to minimum DAC voltage output.
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...