Appendix C– DTR Remote M&C Protocol
CG-6073 (Rev R, June, 2012)
33
MINIMUM REF LVL
Path:
/ CONFIGS OPERATION ANALOG-OUTPUTS DAC2 DAC2-REF
Type:
Data Editor
Syntax:
REFERENCE [= n] | [D]
Range:
Real: -150.0 .. 20.0
Notes:
The MINIMUM REF POWER LVL is the minimum input power level reference which
corresponds to minimum DAC voltage output.
MUTE
Path:
/ CONFIGS MONOPULSE
Type:
Data Editor
Syntax:
MUTE [= n] | [D]
Range:
Integer:
0 .. 1
0
Disabled
1
Enabled
Notes:
MUTE controls the combination of signal and error channels in the monopulse
hardware. Disable to include the error channel for monopulse operation. Enable to
exclude the error channel for normal operation. NOTE: This can also be set by
M&C commands in TRL-Emulation.
MUTE FAULT
Path:
/ CONFIGS MONOPULSE
Type:
Data Editor
Syntax:
MUTE-FAULT [= n] | [D]
Range:
Integer:
0 .. 1
0
Disabled
1
Enabled
Notes:
MUTE-FAULT enables or disables the mute switch fault. This feature should be
disabled for monopulse plates which do not support mute switch feedback.
Disabling the fault on systems that support mute switch failure detection is not
recommended for normal operation. Feedback is provided via mute status lines on
I/O interface 2.
Summary of Contents for CG-1220
Page 6: ...vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...Table of Contents x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ......
Page 54: ...Maintenance 5 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 56: ...Engineering Drawings 6 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 65: ...Appendix C DTR Remote M C Protocol CG 6073 Rev R Jun 2012 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...Remote M C Protocol C 2 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...
Page 134: ...Acronyms Abbreviations D 4 CG 1220 DTR THIS PAGE INTENTIONALLY LEFT BLANK...