Connecting to Power Source

This air compressor is designed to operate on a 
properly grounded 120 volt, 60Hz, single phase, 
alternating current (ac) power source with a fused 
20 amp time delayed fuse or circuit breaker. It is 
recommended that a qualified electrician verify 
the ACTUAL VOLTAGE at the receptacle into 
which the unit will be plugged and confirm that the 
receptacle is properly fused and grounded. The use 
of the proper circuit size can eliminate nuisance 
circuit breaker tripping while operating your air 
compressor.

Extension Cords

For optimum Air Compressor performance an 
extension cord should not be used unless 
absolutely necessary. If necessary, care must be 
taken in selecting an extension cord appropriate 
for use with your specific Air Compressor. Select a 
properly grounded extension cord which will mate 
directly with the power source receptacle and the 
Air Compressor power cord without the use of 
adapters. Make certain that the extension cord is 
properly wired and in good electrical condition.
Maximum length of extension cord should be 50 
feet. Minimum wire size of extension cord should be 
12 gauge.

Attaching an Air Hose

Your Air Compressor is supplied with a 1/4" Quick 
Disconnect Air Chuck. Once you have correctly 
installed the Air Chuck (See Installing the Air Chuck) 
your compressor will be ready to accept air hoses 
equipped with 1/4" male air couplers.

Note:

  Use only air hoses rated for use with 115psi

air pressure or higher.
To install an air hose, equipped with a 1/4" male 
coupler:
1.   Pull back on Air Chuck outer sleeve to allow 

coupler to be fully inserted into Air Chuck.

2.   Insert coupler into Air Chuck.
3.  Release outer sleeve of Air Chuck.
4.   Verify that air hose is securely connected to Air 

Chuck by pulling lightly on air hose.

Adjusting the Air Pressure

Your Air Compressor is supplied with an Air 
Pressure Regulator. This Regulator adjusts the air 
pressure.
 

To increase air pressure, turn Air Regulator 

clockwise.
 

To decrease air pressure, turn Air Regulator 

counterclockwise.

Cold Weather Starting

Temperatures below freezing (32°F) cause the 
metal parts of your Air Compressor to contract and 
that makes starting more difficult. To assist the Air 
Compressor in starting in cold weather, follow 
these tips:
1.   Try to keep Air Compressor stored in 

temperatures above 32° fahrenheit.

2.   Open the Air Tank Drain Valve and release all air 

pressure from the Air Tank before attempting to 
start in cold weather. (After air is released from 
Air Tank, close Drain Valve.)

3.   Plug Air Compressor directly into a 120 volt 

electrical outlet. Do not use an extension cord 
when starting your Air Compressor in cold 
weather.

MAINTENANCE

Daily (or before each use)

1.   Check oil level
2.   Drain condensation from the air tank.
3.   Check for any unusual noise or vibration.
4.   Be sure all nuts and bolts are tight.

Weekly

1.  Clean breather hole on Oil Breather Cap.

Monthly

1.   Inspect air system for leaks by applying soapy 

water to all joints. Tighten these joints if leaks 
are discovered.

6 Months

 (or after 250 hours of operation - 

whichever comes first)
1.  Change Air Compressor Oil.

Note:

 Change oil more often if Air Compressor is 

used near paint spraying operations or in dusty 
environments.

Checking the Air Compressor Oil

1.   Place Air Compressor on level surface. The oil 

level should be at the red dot on the Oil Sight 
Glass.

2.   If oil level is low, remove Oil Breather Cap and 

add enough oil to bring the oil level to the red 
dot on the Oil Sight Glass.

3.   Replace Oil Breather Cap before starting 

compressor.

Changing the Air Compressor Oil
Note:

 This compressor uses only SAE 5W-30 oil.

1.   Remove the Oil Sight Glass by turning counter 

clockwise with wrench.

Note:

 Oil will begin to drain as Oil Sight Glass is 

loosened. Place a funnel and oil pan under the Oil 
Sight Glass BEFORE loosening.
2.   Once Oil Sight Glass is removed, tilt Air 

Compressor backwards to allow all of the oil to 
drain out of the crankcase.

Summary of Contents for 857647 005024

Page 1: ...UAL R servoir de 4 gallons 16 litres Compresseur Air MANUEL D INSTRUCTIONS Model Mod le n AC1103 UPC 857647 005024 General International Power Products LLC 6243 Industrial Parkway Whitehouse OH 43571...

Page 2: ...English...

Page 3: ...ontact your retailer or our support line with the model and serial number of your unit for clarification To file a Claim To file a claim under our Standard 2 year Limited Warranty all defective parts...

Page 4: ...ired while taking drugs If there is any doubt do not attempt to operate 10 Use safety equipment Eye protection should be worn at all times when operating this tool Use ANSI approved safety glasses Eve...

Page 5: ...al air filter keeps your compressor running cleanly by filtering out impurities Oil Breather Cap As the compressor motor operates pressurized air must be released from the crank case The oil breather...

Page 6: ...nstalling Oil and Oil Breather Cap section Initial Start Up Procedure 1 Open the Air Tank Drain Valve to permit air to escape preventing air pressure buildup in the air tank 2 Run the compressor for a...

Page 7: ...egulator This Regulator adjusts the air pressure To increase air pressure turn Air Regulator clockwise To decrease air pressure turn Air Regulator counterclockwise Cold Weather Starting Temperatures b...

Page 8: ...of the red dot on the Oil Sight Glass 7 Install the Oil Breather Cap into the oil fill hole Firmly hand tighten the Oil Breather Cap by turning clockwise Always inspect the tool before use and make s...

Page 9: ...7 English 7...

Page 10: ...de soutien technique et mentionner le num ro de mod le et de s rie de votre machine afin d obtenir des claircissements DEMANDE DE R CLAMATION Pour pr senter une demande de r clamation en vertu de not...

Page 11: ...l cart de l aire de travail Ne laissez jamais un enfant manipuler un outil sans la supervision vigilante d un adulte 9 vitez d utiliser cet outil si vous tes sous l emprise de la drogue ou de l alcool...

Page 12: ...LIARISEZ VOUS AVEC VOTRE COMPRESSEUR Poign e La poign e pratique avec prise en caoutchouc facilite le transport de votre compresseur d air R gulateur d air Le r gulateur d air contr le la pression du...

Page 13: ...Vissez le mandrin pneumatique dans le r gulateur d air en le tournant dans le sens horaire 2 Serrez solidement le mandrin pneumatique l aide d une cl Remarque NE SERREZ pas trop le mandrin pneumatiqu...

Page 14: ...ement dans la prise de courant de la source d alimentation et dans le cordon d alimentation du compresseur d air sans adaptateur Assurez vous que la rallonge est bien c bl e et en bon tat Sa longueur...

Page 15: ...cipient huile sous l ouverture AVANT de desserrer le voyant de niveau d huile 2 Une fois que le voyant de niveau d huile est retire inclinez le compresseur d air vers l arri re pour permettre l huile...

Page 16: ...14 Fran ais...

Reviews: