13
AC1220 man
v.190926
Air Compressor
BEFORE EACH USE
WARNING
• Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose
whip.
• Risk of unsafe operation. Do not use damaged or worn accessories.
•
Risk of bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s
maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed
the maximum pressure rating.
DUTY CYCLE: This air compressor pump is capable of running continuously. To prolong the life of your
air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air
compressor pump should not run more than 30-45 minutes in any given hour.
ACCESSORIES
Accessories for this unit are sold separately.
Attaching an air hose
Your air compressor is supplied with a 1/4" push-connect air coupler (fig.3) . With a factory-installed air
coupler, your compressor is ready to accept air hoses
equipped with 1/4" male air connectors (fig 4).
Use only air hoses rated for use with
150 psi air pressure or higher.
To install any air hose equipped with a 1/4" male
connector (fig 4)
:
1.
Simply push the "connector" or "plug" into the
fitting and it automatically engages.
2. Verify that air hose is securely connected to air
coupler by pulling on the air hose.
OPERATING INSTRUCTIONS
WARNING
•
Risk of bursting. If any unusual noise or vibration is noticed, stop the compressor immediately and have
it checked by a trained service technician.
Daily start-up
1. Set the Power Switch to the OFF (0) position (A, fig.2).
2.
Inspect the air compressor, air hose, and any accessories/tools being used for damage or obstruction. If
any of these mentioned items need repair/replacement, contact your local authorized dealer before use.
3.
Close the drain valve (F, fig 2).
NOTICE