FL4000
46
Register
Address
(Hex)
Parameter
Function
Data
Type
Data Range Access
0x00A7 Reserved
Reserved
Numeric
Value
0 R
0x00A8
Warning Event
Count
Total Warning Event
Count
Numeric
Value
0 - 65535
R
0x00A9
Running Time Hi
Running Time Hi for
Alarm Event log entries
Numeric
Value
0 - 65535
R
0x00AA
Running Time Low
Running Time Low for
Alarm Event log entries
Numeric
Value
0 - 65535
R
0x00AB
Clock Time Hi
Hi byte = year, Lo byte
month: Alarm clock time
Numeric
Value
1 –99 year,
1– 12
month
R
0x00AC
Clock Time Mid
Hi byte = Day, Lo byte
Hour: Alarm clock time
Numeric
Value
1 – 31 day,
0 – 23 hour
R
0x00AD
Clock Time Low
Hi byte = Minute, Lo byte
second: Alarm clock time
Numeric
Value
0 – 59
minutes
0 – 59
seconds
R
0x00AE Reserved
Reserved
Numeric
Value
0 R
0x00AF Reserved
Reserved
Numeric
Value
0 R
0x00B0
Alarm Event
Count
Total Alarm Event Count
Numeric
Value
0 - 65535
R
0x00B1
Running Time Hi
Running Time Hi for Fault
Event log entries
Numeric
Value
0 - 65535
R
0x00B2
Running Time Low
Running Time Low for
Fault Event log entries
Numeric
Value
0 - 65535
R
0x00B3
Clock Time Hi
Hi byte = year, Lo byte
month: Fault clock time
Numeric
Value
1 –99 year,
1– 12
month
R
0x00B4
Clock Time Mid
Hi byte = Day, Lo byte
Hour: Fault clock time
Numeric
Value
1 – 31 day,
0 – 23 hour
R
0x00B5
Clock Time Low
Hi byte = Minute, Lo byte
second: Fault clock time
Numeric
Value
0 – 59
minutes
0 – 59
seconds
R
0x00B6
Fault Code
See Table 32
Numeric
Value
0 R
0x00B7 Reserved
Reserved
Numeric
Value
0 R
0x00B8
Fault Event Count
Total Fault Event Count
Numeric
Value
0 - 65535
R
0x00BA
Running Time Hi
Running Time Hi for
Maintenance Event log
entries
Numeric
Value
0 - 65535
R
0x00BB
Running Time Low
Running Time Low for
Maintenance Event log
entries
Numeric
Value
0 - 65535
R