FL4000
68
Recharging Instructions
NOTE
:
Charging must be carried out in a non-hazardous area. The charging receptacle is
located inside the housing adjacent to the ON button. To gain access, it is necessary to
unscrew the knurled plug from the body of the unit. The plug is secured to the ON
button by a safety strap to keep it from being lost.
Insert the charging plug into the receptacle. Complete recharging takes 3.5 hours, minimum.
NOTE
: Replace the plug after charging is complete.
It is recommended that the Test Lamp be kept on charge when not in use to prevent excessive
battery discharge. The batteries may be charged an average of 500 times before the battery
pack must be replaced.
8.5.3 Mounting
Bracket
A mounting bracket is available to mount the FL4000 to a wall, pole, etc. The mounting bracket
design allows for optical alignment adjustments when utilizing to a fixed installation. Please
refer to Figure 16: Detector Mounting and Installation.