Model IR400 HART
11
Event 1 is the one just before that and so forth.
Request Data Bytes
Byte
Format
Description
None N/A
N/A
Response Data Bytes
Byte
Format
Description
0 - 3
Unsigned-32
Event Running Time (in Seconds)
4– 6
Date
Event Date: Day, Month, Year – 1900
7 Unsigned-8 Event
Hour
8 Unsigned-8 Event
Minute
9 Unsigned-8 Event
Second
Byte
Format
Description
10-11 Unsigned-8
Priority
Fault
12-13 Unsigned-16
Event
Cause
– See device specific table
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
Command #148: Read Maintenance Event Log
This reads the Maintenance Event Log as specified by the event log number. Event 0 is the most recent
event. Event 1 is the one just before that and so forth.
Request Data Bytes
Byte
Format
Description
None N/A
N/A
Response Data Bytes
Byte
Format
Description
0
Unsigned-8
Event Log Number
0 - 3
Unsigned-32
Event Running Time (in Seconds)
4– 6
Date
Event Date: Day, Month, Year – 1900
7 Unsigned-8 Event
Hour