Model IR400 HART
18
Command #165: Get Set Up Information
Request Data Bytes
Byte
Format
Description
None N/A
N/A
Response Data Bytes
Byte
Format
Description
0
Unsigned-8
Gas ID
1 Enumerated Measured
Units
2- 5
Unsigned-32
Full Scale
6
Unsigned-8
Alarm level, % of FS
7
Unsigned-8
Reserved = 0
8
Unsigned-8
Reserved = 0
9
Unsigned-8
Warn level, % of FS
10
Unsigned-8
Reserved = 0
11
Unsigned-8
Reserved = 0
12
Unsigned-8
Reserved = 0
13
Unsigned-8
Reserved = 0
14
Unsigned-8
Reserved = 0
15
Unsigned-8
Reserved = 0
16
Unsigned-8
Reserved = 0
17 Unsigned-8
Cal IO type: 0 – zero switch, 1 – manual solenoid, 2 – automatic
solenoid
18-19
Unsigned-8
Reserved = 0
20
Unsigned-16
Reserved = 0
21
Unsigned-8
Reserved = 0
22
Unsigned-8
Cal level, % of FS.
23
Unsigned-8
Reserved = 0
24
Unsigned-8
Current Range: 0 = 3.5 – 20mA, 1 = 1.25 – 20mA
Command-Specific Response Codes
Code
Class
Description
0
Success
No Command-Specific Errors
1-127
Undefined
Summary of Contents for IR400
Page 2: ......
Page 15: ...Model IR400 11 Figure 5b IR400 Mounting Dimensions with a European Box ...
Page 20: ...Model IR400 16 Figure 7 Wiring Diagram from IR400 to Control Equipment ...
Page 41: ...Model IR400 37 9 6 Engineering Documentation ...
Page 45: ...Model IR400 HART Field Device Specification for Point IR Gas Detector ...
Page 78: ...Model IR400 Infrared Point Detector for Hydrocarbon Gas Applications Modbus programming guide ...