Model IR400 MODBUS
9
byte Hour: Fault
clock time
Value
0 – 23 hour
00CCh
Clock Time Low
Hi byte = Minute,
Lo byte second:
Fault clock time
Numeric
Value
0 – 59 minutes
0 – 59 seconds
R
00CDh
Fault Code
See
Numeric
Value
0
R
00CEh
Reserved
Reserved
Numeric
Value
0
R
00CFh
Fault Event
Count
Total Fault Event
Count
Numeric
Value
0 - 65535
R
00D0h
Running Time
Hi
Running Time Hi
for Maintenance
Event log entries
Numeric
Value
0 - 65535
R
00D1h
Running Time
Low
Running Time Low
for Maintenance
Event log entries
Numeric
Value
0 - 65535
R
00D2h
Clock Time Hi
Hi byte = year, Lo
byte month:
Maintenance clock
time
Numeric
Value
1 –99 year, 1–
12 month
R
00D3h
Clock Time Mid
Hi byte = Day, Lo
byte Hour:
Maintenance clock
time
Numeric
Value
1 – 31 day,
0 – 23 hour
R
00D4h
Clock Time Low
Hi byte = Minute,
Lo byte second:
Maintenance clock
time
Numeric
Value
0 – 59 minutes
0 – 59 seconds
R
00D5h
Reserved
Reserved
Numeric
Value
0
R
00D6h
Reserved
Reserved
Numeric
Value
0
R
00D7h
Maintenance
Event Count
Total Maintenance
Event Count
Numeric
Value
0 - 65535
R
00D8h
Running Time
Hi
Running Time Hi
for Calibration
Event log entries
Numeric
Value
0 - 65535
R
00D9h
Running Time
Low
Running Time Low
for Calibration
Event log entries
Numeric
Value
0 - 65535
R
00DAh
Clock Time Hi
Hi byte = year, Lo
byte month:
Calibration clock
time
Numeric
Value
1 –99 year, 1–
12 month
R
00DBh
Clock Time Mid
Hi byte = Day, Lo
byte Hour:
Calibration clock
time
Numeric
Value
1 – 31 day,
0 – 23 hour
R
Summary of Contents for IR400
Page 2: ......
Page 15: ...Model IR400 11 Figure 5b IR400 Mounting Dimensions with a European Box ...
Page 20: ...Model IR400 16 Figure 7 Wiring Diagram from IR400 to Control Equipment ...
Page 41: ...Model IR400 37 9 6 Engineering Documentation ...
Page 45: ...Model IR400 HART Field Device Specification for Point IR Gas Detector ...
Page 78: ...Model IR400 Infrared Point Detector for Hydrocarbon Gas Applications Modbus programming guide ...