background image

Jet-Set JM-1000™  

OPERATION 

SET-UP 

1.  Locate the jet near the drain line on a level surface with drainage. 

Tip: Ideally, the drain line should be cleared from the  downstream 
side; that is, from the street back toward the house. If you must 
clear the line from the drain toward the street, you may need to 
use a siphon pump to clear away excess water. 

2.  Check  the  inlet  screen  to  make  sure  it’s  clean  before  each 

use.  

3.  Check that the incoming water supply is clean and free of debris. 

Turn the water source on for at least 15 seconds to remove any 
possible debris in the water before connecting hose to water  inlet. 

4.  Connect one end of a water supply hose to the  water supply and 

the other end to the water inlet of the jet  machine. Water supply 
must be a minimum of 20 psi and not to exceed  80 psi. 

or  dam-

age to the pump can occur. 

Use only heavy duty 5/8” hose of no 

more  than  50  ft.  in  length.  If  operated  without  an  adequate 
water supply, the pump will cavitate. Cavitation causes the pump 
to vibrate,  causing  damage  to  the  pump. 

Note:  Lack  of  water 

supply can lead to seal damage, causing a loss of pressure 
and will  void the warranty to the pump.

 

5.  Maximum temperature from the water source should not  exceed 

90°F  (32°C). 

Using  water  hotter  than  90°F  (32°C)  can  cause 

damage to the pump and void the warranty. 

If jet is being used 

to clear ice blockages, see instructions on Ice Blockages. 

6.  When using a new hose, run water through it to clean it out before 

attaching the nozzle. 

NOZZLE SELECTION GUIDE 

 

HOSE SIZE—1/8”  

 

CAT # 

15° Rear Jets w/No Forward Jet 

JN-1 

15° Rear Jets w/One Forward Jet 

JN-2 

30° Rear Jets w/No Forward Jet 

JN-3 

Spring Leader  

JNSL-1 

Down Head Nozzle (Optional) 

JNDH-1 

Rotary Nozzle* (Optional) 

JN-RA-2 

JN-RB-2 

* Rotary Nozzles can be adapted to 1/8” using AD-3 adapter. 

JET ASSEMBLY  

 

Upon arrival, inspect the shipping carton for damages. Unbox and 

examine  all  parts.  Note  any  damage  to  machine  or  components 
for claims against freight carrier. 

 

Jet machines are meant to be used at or near the  working area 
and under operator supervision. If machine must be located out of 
sight of operator, special controls may be required for proper ma-
chine operation and operator safety 

Wide spray flushing nozzle cleans 

inside of pipe thoroughly. 

Powerful penetrating nozzle cuts 

through grease and ice. 

Spring  leader  nozzles  and  optional 
down  head  nozzles  are  special  noz-
zles  to  help  hose  travel  through  the 

pipe  when  there  are  a  lot  of  Tee’s, 
curves, and bends. 
 
Optional Rotary nozzles are useful as 
a  finishing  tool.  After  the  line  has 

been  cleared,  you  may  switch  to  the 
rotary  nozzle  to  more  thoroughly 
clean the walls of the pipe. Use these 

nozzles  only  in  a  predominantly 
straight run since they are longer than 

regular  nozzles  and  may  get  caught 
in tight bends. 
 

 

Down Head Nozzle  

SPECIALTY NOZZLES  

Spring Leader Nozzle  

Rotary Nozzle  

Summary of Contents for Mini-Jet JM-1000-A

Page 1: ...rs of trouble free profitable service However no ma chine is better than its operator Read understand and follow all safety warnings and instructions provided with the product Failure to follow the warnings and instructions may result in electric shock and or serious injury Save all warn ings and instructions for future reference SAVE THESE INSTRUCTIONS ...

Page 2: ... ignite causing prop erty damage or severe injury Always wear safety glasses and rub ber soled non slip shoes High pres sure spray can cause paint chips or other particles to become airborne and fly at high speeds Use of this safety equipment may prevent serious injury These instructions are intended to familiarize all personnel with the safe operation and maintenance procedures for the JM 1000 DA...

Page 3: ... wet hands Reduces the risk of electric shock GROUND FAULT CIRCUIT INTERRUPTER GFCI Your machine is equipped with a ground fault circuit interrupter which protects you against shock if a short circuit should occur Check that receptacle is properly grounded Test the GFCI before each use 1 Plug into 120 volt receptacle 2 Push test button Indicator light will go out and power to machine should cut of...

Page 4: ...ose Some nozzles may have an orifice in the front to cut through the stoppage All will have holes in the back to drive the hose down the line and clean the walls of the pipe A tight spray pattern 15 has more driving power for long runs a wide spray pattern 30 does a better job of cutting the grease off of the walls of the pipe A combination of nozzles may be required to clear a line Always turn of...

Page 5: ...being used to clear ice blockages see instructions on Ice Blockages 6 When using a new hose run water through it to clean it out before attaching the nozzle NOZZLE SELECTION GUIDE HOSE SIZE 1 8 CAT 15 Rear Jets w No Forward Jet JN 1 15 Rear Jets w One Forward Jet JN 2 30 Rear Jets w No Forward Jet JN 3 Spring Leader JNSL 1 Down Head Nozzle Optional JNDH 1 Rotary Nozzle Optional JN RA 2 JN RB 2 Rot...

Page 6: ...ater through it to flush out debris before connecting a nozzle 2 Select the correct nozzle and attach to the end of the hose See Nozzle Selection Guide Clean nozzles before and after each use 3 Insert the jet hose 2 to 3 feet into the drain line before turning on machine 4 Turn on the water supply valve fully to allow for maximum flow 5 Turn ON shut off valve at the end of the supply hose 6 Allow ...

Page 7: ... plumbing or air leak in inlet plumbing Repair clogged inlet fittings Check supply hose and ensure adequate water supply Damaged pump Replace any damaged pump parts and clean out any foreign particles Clogged nozzle Clean or replace nozzle Water leakage at intake Worn pump Repair or replace pump Inadequate water supply to pump creating a vacuum lock Ensure adequate tap water supply Clear inlet fil...

Page 8: ...Jet Set JM 1000 General Wire Spring Co 1101 Thompson Avenue McKees Rocks PA 15136 412 771 6300 www drainbrain com General Wire Spring Co 2018 C JM 1000OI 1218 ...

Reviews: