Air velocity, Air flow, Type K/J thermometer

Real time data logger, 16000 Data logger no., RS232

ANEMOMETER

Model : DAF2005MDL

Summary of Contents for DAF2005MDL

Page 1: ...Air velocity Air flow Type K J thermometer Real time data logger 16000 Data logger no RS232 ANEMOMETER Model DAF2005MDL...

Page 2: ...12 5 ADVANCED ADJUSTMENT PROCEDURE 14 5 1 Check Memory Space 15 5 2 Clear Memory 15 5 3 Date Time Setting 15 5 4 Sample Time Setting 16 5 5 Auto Power Off Default Setting 16 5 6 Temp Unit Default Sett...

Page 3: ...emp unit Air flow measurement can set the area dimension Multi function with easy operation Low friction ball vane wheels make sure high accuracy in high low velocities Metal vane high reliability Lar...

Page 4: ...hour Air flow CMM m 3 min cube meter per min CFM m 3 min cube feet per min Air temperature Type K Type J thermometer Sampling Time Manual Push the data logger button of Data Logger once will save data...

Page 5: ...Less than 80 R H Humidity Power Supply DC 1 5 V battery UM3 x 4 PCs main instrument Heavy duty type DC 9V adapter input AC DC power adapter is optional Power Supply DC 3V silver battery clock module T...

Page 6: ...0 m S 0 1 m S 2 0 2 m S Km h 1 4 108 0 Km h 0 1 Km h 2 0 8 Km h Mile h 0 9 67 0 Mile h 0 1 Mile h 2 0 4 Mile h Knots 0 8 58 3 Knots 0 1 Knots 2 0 4 Knots Ft min 80 5910 Ft min 1 Ft min 2 40 Ft min Air...

Page 7: ...0 5 50 1 to 100 0 0 2 1 0 1 58 0 to 2372 0 0 2 1 58 1 to 148 0 0 2 1 8 Type J 0 1 100 0 to 1100 0 0 2 0 5 50 1 to 100 0 0 2 1 0 1 58 0 to 2012 0 0 2 1 58 1 to 148 0 0 2 1 8 Above specification tests...

Page 8: ...3 FRONT PANEL DESCRIPTION 6...

Page 9: ...ogger Button 3 9 Stand 3 10 Battery Compartment Cover 3 11 Tripod Fix Nut 3 12 LCD Brightness Adjust VR 3 13 System Reset Switch 3 14 RS 232 Output Terminal 3 15 DC 9V Power Adapter Input Socket 3 16...

Page 10: ...e Probe Plug 3 19 Fig 1 into the Probe Input Socket 3 17 Fig 1 Attention After install the Probe Plug should slide Probe Lock Switch 3 18 Fig 1 to the On position right position 2 Power on the meter b...

Page 11: ...to face against the air flow 4 2 Air flow CMM CFM measurement 1 Install the Probe Plug 3 19 Fig 1 into the Probe Input Socket 3 17 Fig 1 Attention After install the Probe Plug should slide Probe Lock...

Page 12: ...ig 1 will show air flow value Measuring Consideration The yellow dot mark on the sensor head indicates the direction that need to face against the air flow 4 3 Thermocouple Type K J Thermometer measur...

Page 13: ...LD symbol Press the Hold Button once again will release the data hold function 4 5 Data Record Max Min reading The data record function records the maximum and minimum readings Press the REC Button 3...

Page 14: ...ck time Real time data logger build in clock hour min sec year month date The data logger procedures are as following a If push the Logger Button 3 8 Fig 1 once will show the sampling time value on th...

Page 15: ...e Full it indicate the memory data already over 16 000 no and the memory is full f During the Data Logger function is executed press the Logger Button 3 8 Fig 1 once will stop to execute the data logg...

Page 16: ...il the lower display show XXXXX Memory Space If push the ESC Button 3 3 Fig 1 will escape the selecting function and return to the normal measuring display b One by one to press the Set Button 3 8 Fig...

Page 17: ...XX is the balance data numbers for example XXXXX 15417 5 2 Clear Memory To delete the existing save data numbers from the memory Push ENTER Button once then push ENTER Button to confirm Press the ESC...

Page 18: ...f Default Setting Use Up Button Down Button to select 1 or 0 1 Auto power On 0 Auto power Off After finish the Auto Power Off adjustment push the Enter Button then press the ESC Button will quite and...

Page 19: ...e Air Flow unit adjustment push the Enter Button first then press the ESC Button again will quite and return to the normal measurement display 5 9 Area Size Air Flow Default Setting Use Up Button Down...

Page 20: ...on first The display will not show the HOLD and the REC marker 2 Press the SEND Button 3 7 Fig 1 at least 2 seconds until the bottom right display show Transmit mode then release the button LCD displa...

Page 21: ...tton following push the Logger button to save the data the display will show the REC and DATA After save the data push the Logger button following push the REC button will exist the Data Logger functi...

Page 22: ...right display will show the Transmit mode indicator again 5 Push the ESC Button 3 3 Fig 1 will exist the data sending function and return to the normal display Remarks If intend up load the data to t...

Page 23: ...for user s specific application A RS232 lead with the following connection will be required to link the instrument with the PC serial port Meter PC 3 5 mm jack plug 9W D Connector Center Pin Pin 4 Gr...

Page 24: ...position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D10 Polarity 0 Positive 1 Negative D11 Annunciator for Display D12 01 Knot 09 mile h 12 02 Km h 10 CMM 84 m S 08 ft min 11 CFM 85 D13 When...

Page 25: ...led it is necessary to replace the battery CR2032 2 Slide the Battery Cover 3 10 Fig 1 away from the instrument and remove the battery 3 Replace with batteries UM3 1 5 V x 4 PCs or CR2032 and reinstat...

Page 26: ...uter Data Logger Software the used to download software the data logger data recorder SW DL2005 from the meter to computer Data Acquisition The SW U801 WIN is a multi software displays 1 2 4 6 8 displ...

Page 27: ...ble for many general purpose application Thermocouple Measure Range 50 to 900 Probe 50 to 1650 Type K TP 02A Dimension 10cm tube 3 2mm Dia Thermocouple Measure Range 50 to 1200 Probe 50 to 2200 Type K...