4
• Built-in Non-Contact Voltage (NCV) detector with four
sensitivity settings and audible and visual alerts
• Large backlit digital LCD with two 6000-count
readouts for simultaneous display of real-time
current or voltage on primary readout and line
frequency on secondary readout
• Fast-response analog bar graph
• Bright LED work light
• Manual ranging and MIN/MAX display options
• Data HOLD and REL (zero) buttons
• INRUSH mode for measuring surge current during
motor startup
• 1.65 in. (42mm) jaw opening (largest in its class) for
conductors up to 550 MCM resists side torque
• Rugged housing can survive multiple drops onto
concrete from height of 5 ft. (1.6m)
• 20-minute Auto Power Off (APO) function can be
disabled
• ETL certified CAT III 600V, CAT II 1000V
• 3 year limited warranty
WHAT’S IN THE BLISTER PACK
The meter is supplied in a blister pack with a cavity in
the rear for a soft black nylon carrying pouch. Inside
the pouch are a set of double-insulated test leads
with screw-on alligator clips, a “K” type stem
thermocouple probe and plug adapter, 3 “AAA”
batteries and this user’s manual.
PRODUCT OVERVIEW
Fig. 1 shows the labels and positions of the controls,
indicators and physical structures of the CM660 and
CM700. Fig. 2 shows all possible indications on the
LCD of either unit. Familiarize yourself with the
functions and meanings of these controls, indicators
and connectors before moving on to the Setup
Instructions and Operating Instructions.