background image

Product Display Layout

RECEIVER

RECEIVER LED DESCRIPTIONS

ROOM THERMOSTAT PLACEMENT

Room Thermostat needs to be placed in the room which is used most frequently. 

For instance; living room or lounge. Placing the Room Thermostat in a spot that 

have air circulation like entrance of a room or side of window should be avoided. 

Also anywhere close to heating/cooling units such as radiator, stove and spots 

which get direct sun lights would not be suitable. Room Thermostat needs to be 

located above the floor 150 cm height. Few trials may be made to find the most 

convenient spot.

GENERAL SPECIFICATIONS

SOLARA  330S  RF 

is  a  wireless  room  thermostat.  The  user  can  get  more 

comfortable and economic heating/cooling by adjusting the room thermostat with 

the required temperature.

Daily and Weekly Programming

Different Mode Options (Comfort, Economy, Holiday)

Heating Calibration

                         

ON/OFF Control

                    

Wireless Connection

Heating/Cooling Option

                 TPI Algorithm

Precise Temperature Measurement

SOLARA 330S RF 

and EQUIPMENTS

TECHNICAL DATA

Room Thermostat

Receiver

ROOM THERMOSTAT
Button Functions

BATTERY PLACEMENT

Press  the  screwdriver  forward  from  the  space  at  the  bottom  of  the  Room 

Thermostat, bend the tabs and separate the front cover. Insert 2 new AAA alkaline 

batteries in the battery housing with the correct battery direction. Replace both 

batteries at the same time. Align the front part  of your Room Thermostat with 

corresponding slot on the back, and then push gently until the thermostat snaps 

into place.

Low Battery Warning: 

When the “ 

       

” icon appears on the screen, it means “low 

battery warning”. It is recommended to replace the batteries when this warning 

appears. 

Warning:

 

When  the  product is  not  used  for  a  long  period  (more than  15  days), 

remove the  batteries.  Otherwise,  malfunctions  that  may occur  would  be  out  of 

warranty. Please throw your dead batteries into the waste bin for batteries.

RECEIVER PLACEMENT

The important things to note for the Receiver placement are 

avoiding  physical  contact  between  the  Receiver  and 

heating/cooling  unit,  and  protecting  it  against  materials 

such as liquid, dust etc.

The devices should be placed in order to minimize the damage to the received and 
transmitted signals by paying attention to the following points;

The devices should not be mounted on metal surfaces. 

 The  devices  should  not  be  installed  close  to  electrical  cables  and  electronic 

equipment such as computers and television units.

 The devices should not be installed near large metal structures or other building 

materials using fine metal meshes such as special glass or special concrete. 

 Distance between the Room Thermostat and the Receiver should not exceed 20 

meters or 2 floors. 

Receiver must be installed at least 50 cm away from the heating/cooling unit.

RECEIVER SETUP

First, shut down your heating/cooling unit and your heating/cooling unit's power 

source with all electrical current (fuse, socket etc.)

As shown in the connection diagram, connect one end of the heating/cooling unit 

connection cable to the COM and the other to the NO input of the Receiver. 

Connect the other ends of the cable -which you connected to the Receiver-   to 

room thermostat connection terminal as shown in your heating/cooling unit's 

user manual. 

You must first connect the Receiver power cable to the Receiver and then to the 

fuse which the heating/cooling unit is connected. 

After completing the cable connection process, firstly turn on your fuse and then 

your heating/cooling unit. 

By pressing the Receiver's manual usage button for 2 seconds, you should see 

the Orange Light blinking on the Receiver. In this way, after making sure that the 

heating/cooling unit is operating, press the same button again for 2 seconds and 

see that the Orange LED turns off. 

Set up the Room Thermostat to pair the Receiver with the Room Thermostat.

RECEIVER WIRING DIAGRAM

Warning! 

Operations within the heating / cooling unit or the electrical installation must be 

carried out by professionally qualified persons. 

1

2

3

85mm / 125mm / 20mm

3V DC (2 x AAA 

alkaline battery

)

o

0.1 C

o

o

(5 C) – (30 C)

Year 

(2 x AAA)

o

o

(-10 C) – (+50 C)

o

o

(-20 C) – (+60 C)

Dimensions          

Operating Current

Temperature Measurement Accuracy 

Operating Temperature Range 

Battery Life 

Operating Temperature 

Storage Temperature

Alkaline Battery

Holder

4

Weekly Program Button

Heating & Cooling Option

Mode Button

Temperature Adjustment Button (To Increase)

Temperature Adjustment Button (To Decrease)

On/Off Button – Unlock Button

1

2

3

4

5

6

1

A

A

A

A

A

A

90mm / 90mm / 25mm

230V AC

7A (240VAC – 

Resistive 

L

oad

)

10A (120VAC – 

Resistive 

L

oad

o

o

(-20 C) – (+60 C)

Dimensions 

Operating Current 

Relay NO Switching Current

Storage Temperature

Dowels and Screws

Receiver

ENGLISH

generallife.com.tr

DIGITAL ROOM THERMOSTAT

SOLARA 330S RF 

USER MANUAL

SOLARA 330S RF

Room Thermostat

2

3

4

5

6

1

2

3

4

5

6

9

11

12

7

10

Hour Indicator

Room Temperature

Economy Mode

Comfort Mode

Holiday Mode

Weekly Program Mode

Day Indicator

Screen Lock

Battery Indicator

Set Temperature

Heating Indicator 

- If the Heating Indicator is blinking, the heating unit is working. 

- If the Heating Indicator is steady, the heating unit is not working.

Cooling Indicator 

- If the Cooling Indicator is blinking, the cooling unit is working. 

- If the Cooling Indicator is steady, the cooling unit is not working.

1

2

3

4

5

6

7

8

9

10

11

12

Steady Red

Blinking Green

Steady Green

3 Short Orange Blinking

Steady Orange

3 Short Green Blinking

Blinking Orange

Blinking Red

Receiver has power but Receiver and Room Thermostat

are not paired.

Waiting for pairing signal from the Room Thermostat.

Receiver and Room Thermostat are paired.

Heating/cooling unit is not operating.

Operate the heating/cooling unit signal has reached to

the Receiver.

Heating/cooling unit is operating.

Shut the heating/cooling unit down signal has reached

to the Receiver.

Heating/Cooling unit operates in manual mode.

Receiver did not get any signal from the Room

Thermostat for 22 minutes or longer.

Heating/cooling unit has shut down.

min. 20 cm

4

1

2

3

1-

Manual Operation Button: 

Deactivates the 

Receiver and allows you to use heating/cooling 

unit manually.

2-

Pairing Button: 

Allows pairing the Receiver 

with the Room Thermostat.

3-

Receiver LED Light 

4-Receiver Power Cable Input 
5-Heating/Cooling Unit Connection Cable Input

5

8

COM

NO

AC

(230V)

HEATING/COOLING UNIT

PAIRING

 

THE ROOM THERMOSTAT AND THE RECEIVER

Primarily press the sync button of 

the R

eceiver for 2 seconds and see blinking 

green light of 

the R

eceiver. 

While your device is turned off, press and hold the "On/Off" button for 3 seconds. 

Press the button until the “ 

         

” menu appears. 

Press  the  “Up”  or  “Down”  button  of  your  Room  Thermostat  while  the  LED  is 

flashing green. 

If the pairing is successful, the green flashing LED on the 

R

eceiver will be steady. 

Receiver and Room Thermostat have been paired to each other.

ROOM THERMOSTAT TEMPERATURE CALIBRATION 

Temperature sensors which are used in Room Thermostats are highly sensitive. 

You may need to calibrate your Room Thermostat if you would like to get the same 

temperature values with other thermometers in your living space. 

While your device is turned off, press and hold the “On/Off“ button for 3 seconds. 

Press the "On/Off" button until the “ 

             

” menu appears. In order to see the 

desired  temperature,  set  the  temperature  difference  by  pressing  the 

“Temperature Adjustment Buttons”. This value can be arranged between “-8° C" 

and “+8° C". 

In order to save the settings and exit, press the "On/Off" button until the device 

turns off. 

Note:

 Recommended temperature calibration is “0.0°C”.

FACTORY SETTINGS RESET

Temperature sensors which are used in Room Thermostats are highly sensitive. 

You may need to calibrate your Room Thermostat if you would like to get the same 

temperature values with other thermometers in your living space. 

While your device is turned off, press and hold the “On/Off” button for 3 seconds. 

Press the “On/Off” button until 

the 

“ 

        

” menu appears. 

While in the “ 

        

” menu, select the “ 

       

” option by using 

the 

“Up” or “Down” 

buttons and press the “On/Off” button. 

Your device will be turned off and reset to factory settings.

KEY LOCK

In  the  Room  Thermostat  there  is  a  key  lock  function  to  avoid  any  unintended 

contact. 

In order to unlock the Room Thermostat's key lock 

the 

“On/Off” button should be 

pressed for 3 seconds. If buttons on Room Thermostat are not touched for 10 

seconds, key lock will be reactivated.

DAY AND HOUR SETTINGS

While your Room Thermostat is on, keep pressing 

the “

Weekly Program

 button 

for 3 seconds. 

At the first screen that appears, hour part will be blinking. You may set the time 

with 

the “

Up

 and 

Down

 buttons. 

After setting the time, 

the “

Heating & Cooling Option

 button needs to be pressed 

once. For minute setting, minute part will be blinking. You may set the minute with 

the “

Up

 and 

Down

 buttons. 

After  setting  the  minute, 

the  “

Heating  &  Cooling  Option

  button  needs  to  be 

pressed once to set the day of the week.

Monday has set as the first day of the week and indicated with number 

1

"

.

Numbers  indicate  the  following  days  respectively  2-Tuesday,  3-Wednesday, 

       

4-Thursday, 5-Friday, 6-Saturday and 7-Sunday

When setting is done, you may exit by pressing the “Weekly Program” button for 3 

seconds.

MODE SETTING

Your Room Thermostat has 5 different modes. 3 of them (Comfort, Economy and 

Holiday  Mode)  are  preset  modes.  Other  modes  are  manual  mode  and  weekly 

program mode.

In preset modes, temperature values are based on user's choices which have been 

set in the beginning. Manual mode allows the Room Thermostat to operate within 

the temperature which is required and set directly by user. Weekly Program mode 

continues to work according to the weekly schedule determined by the user.

In order to change the temperature values of preset modes:

Press and hold the “Mode” button for 3 seconds while your Room Thermostat is 

on. 

Comfort Mode temperature value will appear. You may adjust the temperature 

value of Comfort Mode by pressing 

the 

“Up” and “Down” button

s

.

 When setting is done, you may adjust the temperature value of Economy Mode 

with 

the 

“Up” and “Down” button

s

 by pressing the “Mode” button again.

 You may exit

 

the setting screen by pressing the “Mode” button 3 seconds.

 In order to change the manual mode temperature, press the “Up” or “Down” button 

while in the main screen. The Room Thermostat will switch to Manual Mode once 

pressed 

the 

“Up” or “Down” button.

You may press the “Mode” button to switch to the other modes.

MODES

PRESET MODES

WEEKLY

PROGRAM

MODE 

MANUAL MODE

Comfort

Mode

Economy

Mode

Holiday

Mode

Summary of Contents for SOLARA 330S RF

Page 1: ...0 1 C o o 5 C 30 C 1 Year 2 x AAA o o 10 C 50 C o o 20 C 60 C Dimensions Operating Current Temperature Measurement Accuracy Operating Temperature Range Battery Life Operating Temperature Storage Temp...

Page 2: ...If the Cooling Indicator is blinking the cooling unit is working If the Cooling Indicator is steady the cooling unit is not working 1 2 3 4 5 6 7 8 9 10 11 12 Steady Red Blinking Green Steady Green 3...

Page 3: ...s The devices should not be installed near large metal structures or other building materialsusing nemetalmeshessuchasspecialglassorspecialconcrete Distance between the Room Thermostat and the Receive...

Page 4: ...are not touched for 10 seconds keylockwillbereactivated DAY AND HOUR SETTINGS While your Room Thermostat is on keep pressing the Weekly Program button for3seconds At the rst screen that appears hour p...

Page 5: ...h has been set without making any changes press the Weekly Program button once while your Room Thermostat is on Press the Up and Down buttons to see the days press the Mode button to seethesettingsbet...

Page 6: ...mation about your heating cooling unit from your heating cooling unitoperatingmanualorfromyourheating cooling unitservice HowwillIconnectmyheating cooling unitwithmyReceiver We recommend that the conn...

Page 7: ...ronmentsarenotcoveredbythewarranty 13 When the product is not used for a long period more than 15 days remove the batteries Otherwise malfunctionsthatwilloccurareoutofwarranty 14 Damages that may occu...

Page 8: ...NERAL Life Model SOLARA 330S RF Guarantee Period 5 Years Max Time to Repair 20 Days Banderole and Serial Number WARRANTY CERTIFICATE V 01 2022 Vendor Title Address Tel Fax E Mail Invoice Date and Numb...

Reviews: