2.
Keep pressed both buttons “reset/sel” and “drain” and switch Elite Steam back on: the display shows 00 and the spanner
blinks; then release the two
buttons.
3.
Keep pressed “reset/sel” until the display shows 03. WARNING: do NOT confirm any value higher than 04. In case, press “reset/sel” until the display goes
back to the normal operating mode and restart from step 1.
4.
Press “drain” (min. 1 second) to confirm: the hour counter will be reset at once and Elite Steam will go back to the normal operating mode.
5.5
Using the E2 Humidistat
Press
to select
OFF, MANUAL
or
AUTO mode
(if outdoor sensor is connected).
OFF mode:
The humidifier is turned off.
MANUAL mode:
The E2 will work to maintain the single humidity selected. You can set your desired humidity level by pressing
or
. The humidifier will turn ON or OFF according to your manual setting. (The humidifier will operate when the measured relative
humidity falls more than 2% below the set point.) Humidity will have to be lowered when weather is colder or if condensation is
suspected.
Suggested Setting Outdoor Temperatures
15%
-20˚F -29˚C
20%
-10˚F -23˚C
25%
0˚F -18˚C
30%
+10˚F -12˚C
35%
+20˚F - 7˚C
40%
+30˚F - 1˚C
AUTO mode:
The E2 will automatically raise the humidity as the outdoor temperature increases. This provides the highest possible
humidity. The E2 will automatically lower the humidity as temperatures drop. This minimizes the risk of condensation on cold surfaces
like windows. You can adjust the Auto Humidity Index Set Point from 0 (low) to 10 (high) by pressing
or
. The Humidity Index is
based on the outdoor temperature and indoor humidity. The humidifier will switch ON/OFF according to the calculated auto humidity
index set point. Lower Index settings are for older homes with less insulation and vapor barriers. Higher Index settings are for newer
homes with complete vapor barriers, triple pane windows and high R-value insulation. If condensation occurs reduce Index setting by 2
points until condensation stops.
NOTE
If the outdoor temperature sensor fails,
flashes and the unit will default to
MANUAL mode
.
•
To toggle between indoor / outdoor temperature and indoor humidity:
Press .
•
To change the temperature unit:
Press
°C / °F
.
•
To set the temperature / humidity offset in MANUAL or AUTO mode:
1. Simultaneously press
and
when viewing the temperature or humidity reading.
2. Use
or
to change the setting (-3 to 3).
3.
Press
and
simultaneously or wait 5 seconds to confirm and move onto the next setting.
•
Lo
or
Hi
will flash on the display when:
MEASURE
MENT
LO HI
Indoor temp.
Below
0
o
C
(32
o
F)
Above
99
o
F(37
o
C)
Outdoor
temp.
Below -
40
o
C (-
40
o
F)
Above
50
o
C
(122
o
F)
Humidity Below
10%
Above
90%
•
If power is lost, current settings are retained.
WARNING:
Do not allow excess humidification. Excess humidity can cause condensation and enable mold and mildew growth.