16
Eng
lis
h
6 Generator usage:
WARNING:
Ensure grounding is connected (grounding Rod). Check with an
electrician in case of any doubts.
WARNING:
Never connect the 230 voltage output of the equipment to a
building or house (not even during a power outage). The return of the main
network would clash with the generator's voltage and cause serious damage to the
equipment or even a fire.
WARNING:
Do not connect in parallel with the generators, both will be
damaged and will be a fire hazard.
NOTE:
Do not connect an extension to the exhaust.
NOTE:
If a cable extension is needed, make sure you use a good quality
rubber extension and appropriate section:
60m cable length: use a 2mm
2
cable
100m cable length use a 2.5mm
2
cable
NOTE:
Devices that use an engine such as compressors, water pumps,
saws, radials, etc. require up to 3 times more power for startup. For example, a
500 W water pump would need a 1500 W generator for startup. Verify that charges
upon connection do not exceed the maximum power of the group according to this
indication.
GROUNDING
GROUNDING SYMBOL