75
Englis
h
If the engine does not start in 2 or 3 attempts, close the choke again by turning it
to the left side (CHOKE) and proceed again from point 6.
9
After starting, the lamp in panel pass to green color, allow generator run without
load for a minimum of 2 minutes upon each initial start-up to permit engine
stabilize and increase its temperature softly, then you can connect the loads.
NOTE:
When machine is running the choke must be in the right side
(RUNNING), never keep in left side (CHOKE) or an intermediate position, the
blend would be too rich and the engine would not work properly.
NOTE:
If you reach the end of the rope length abruptly you could damage the
handle or rope spring and it wouldn't be covered by warranty.
Do not let go of the handle after pulling to prevent the handle from hitting the
machine. Move your hand along with the handle until it has coiled back completely.