1N00-510 Genesis 80cm Boat v1.1 02/04 

©Tornado International Ltd. 2003 

-17- 

Confidential 

 Risk  of  personal  injury  or  damage  to  the  equipment.  Only  use  the  power 
supply supplied by Tornado for this equipment. 
Caution! 
 Always replace the power supply fuse with one of identical type and rating. 
The  power  supply  is  designed  to  be  operated  only  in  locations  which  are 
protected from water.  
Caution! 
 Ingress of water will lead to severe damage to the power supply. 
Caution! 
 It  is  important  to  ensure  that  there  is  sufficient  ventilation  to  provide  an 
adequate flow of cooling air over the heat sink at the rear of the unit. 
 
2.19 The Power Supply Lead 
The  PSU  lead  is  used  to  connect  the  power  supply  to  the  transmitter 
motherboard in the master console. It is fitted with a different socket at each 
end.  The socket at each end must be fully inserted into the plug and the catch 
checked  to  ensure  it  is  correctly  latched.  A  damaged  power  supply  lead 
should be replaced. 
Caution! 
 The  power  supply  lead  must  not  be  lengthened  without  reference  to  the 
Tornado technical department. 

Summary of Contents for 1N00-510

Page 1: ...t 1N00 510 User Manual Note This unit is fitted with an updated 2013 design for console steering and forward reverse Please quote OPTICAL set up when discussing parts or service For parts page 2 has s...

Page 2: ...121 772 6056 Ask for Technical Help Parts Accessories 44 0 121 773 1827 0 121 772 6056 Ask for the Parts Dept Unit Sales 44 0 121 773 1827 0 121 772 6056 Katie Roberts Comments 44 0 121 773 1827 Stuar...

Page 3: ...onnel or the public Please take note of the information in shaded areas If you have any questions with regard to the correct installation or operation of the product please contact Tornado Internation...

Page 4: ...this manual before using the equipment This manual contains the following sections 1 00 Operating Procedures 1 01 Opening Instructions 1 02 Closing Instructions 2 00 Detail Overview of the System Here...

Page 5: ...or throw the boat onto the water as this will cause the hull to fracture around the battery holder 8 Repeat operations 5 to 7 for each model 9 Coin and test each playing position in turn to ensure th...

Page 6: ...2 01 Consoles The consoles are made from glass fibre with a blockboard reinforcing for the back wall Regular application of a quality proprietary polish will reduce the harmful effects of sunlight The...

Page 7: ...le number 5 6 The consoles are provided with covers which should be used over night and if it rains during the day A canopy over the consoles is advised to allow your customers to use the attraction d...

Page 8: ...r The cost of each game and any bonus games are displayed in accordance with the settings programmed in the coin acceptors As soon as one or more credits are available the green play button will flash...

Page 9: ...in counters are non re settable Note Although each coin counter counts the coins for its own acceptor the cash box serves two acceptors and is not separated 2 05 Cash Box The cash box is mounted in th...

Page 10: ...d in the centre of the console and is accessed by opening the coin acceptor door It is the distribution centre for the console and has the following parts mounted on it Slave Timer End of Go Sounder C...

Page 11: ...ols Counts the timing pulses generated by the master timer and distributed by the console connecting cable When it has received the required number of pulses control is removed from the driving contro...

Page 12: ...the boat to make a gentle turn If the steering wheel is turned completely to the right the right motor is set to reverse causing the boat to turn in a decreasing arc until it is turning in its own len...

Page 13: ...cular set has less than 12 models Note If your set has less than 12 models it is essential that shorting plugs are fitted to all unused console sockets on the transmitter motherboard The red fault LED...

Page 14: ...ed will lead to poor model performance and damage to the transmitter and receivers The loop output board has a secondary function that of providing a loop output meter which is used to tune the loop a...

Page 15: ...coupling of the output meter to the transmitter It is important that this is understood and that this operation is only carried out during installation or replacement re siting of the loop The core of...

Page 16: ...m of the transmitter motherboard Diagram 2 09 It is the connection for the power supply lead The power is distributed to the rest of the system via the console cables 2 16 Diagnostic Socket This is pr...

Page 17: ...e to the power supply Caution It is important to ensure that there is sufficient ventilation to provide an adequate flow of cooling air over the heat sink at the rear of the unit 2 19 The Power Supply...

Page 18: ...use on the case and a charging meter on each module Caution Always replace the battery charger fuse with one of identical type and rating To improve reliability the modules are fully independent When...

Page 19: ...ust be treated with care Handle only with protective clothing Dispose of in accordance with local laws Caution The battery vents must not be removed for any reason The battery is maintenance free and...

Page 20: ...echargeable battery leaves the manufacturer with a finite life This life is usually expressed in terms of charge discharge cycles Each time a battery is charged and discharged a part of the battery li...

Page 21: ...ed Do not part charge and re use the batteries as this will lead to premature failure Storage If the unit is to be removed from service the correct storage of the batteries is vital As soon as the bat...

Page 22: ...ned as soon as it is removed from the water and before any soiling is allowed to dry Never use any abrasive cleaner on the hull or top The top is removed by unscrewing the catch located at the rear of...

Page 23: ...her position oil might enter the motor causing irreparable damage to the motor When the boat is not in service it must be stored vertically with the bows up This allows the water in the outer shaft an...

Page 24: ...ntil the next sync pulse is received when the procedure is repeated This happens 15 times every second Mounted on the top of the receiver are the model selector buttons and a display During use the di...

Page 25: ...le damage to the motor Thoroughly clean all of the boats and consoles taking care to remove any stubborn marks which daily cleaning has missed 3 03 Monthly Clean and lightly lubricate with petroleum j...

Page 26: ...ervice 1 Charge all of the batteries for 24 hours 2 If the consoles were dismounted remount them Take care not to damage any of the internal components or looms 3 Route the console connecting leads to...