Minimum
(A)
Model
Maximum
(A)
GEN6-100
GEN8-90
GEN12.5-60
GEN20-38
GEN30-25
GEN40-19
GEN60-12.5
GEN80-9.5
GEN100-7.5
GEN150-5
GEN300-2.5
GEN600-1.3
000.00
00.00
00.000
00.000
00.000
00.000
00.000
0.000
0.000
0.000
0.000
0.000
100.00
90.00
60.000
38.000
25.000
19.000
12.500
9.500
7.500
5.000
2.500
1.300
Minimum
(A)
Model
Maximum
(A)
GEN6-200
GEN8-180
GEN12.5-120
GEN20-76
GEN30-50
GEN40-38
GEN50-30
GEN60-25
GEN80-19
GEN100-15
GEN150-10
GEN300-5
GEN600-2.6
000.00
000.00
000.00
00.00
00.000
00.000
00.000
00.000
00.000
00.000
00.000
0.000
0.000
200.00
180.00
120.00
76.00
50.000
38.000
30.000
25.000
19.000
15.000
10.000
5.000
2.600
NOTE:
The power supply can accept values higher by 5% than the table values, however it
is not recommended to program the power supply over the rated values.
GEN750W models
Current programming range
GEN1500W models
Current programming range
7.7.7 Status control commands
Refer to section 7-8 for definition of the registers.
Command
#
Description
1
STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
Table 7-6: OVP programming range
Table 7-7: UVL programming range
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
6
8
12.5
20
30
40
50
60
80
100
150
300
600
0.5
0.5
1.0
1.0
2.0
2.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
7.50
10.0
15.0
24.0
36.0
44.0
57.0
66.0
88.0
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
6
8
12.5
20
30
40
50
60
80
100
150
300
600
0
0
0
0
0
0
0
0
0
0
0
0
0
5.70
7.60
11.9
19.0
28.5
38.0
47.5
57.0
76.0
95.0
142
285
570
MV<actual (measured) voltage>
PV<programmed (set) voltage>
MC<actual (measured) current>
PC<programmed (set) current>
SR<status register, 2-digit hex>
FR<fault register, 2-digit hex>
Example response: MV(45.201),PV(45),MC(4.3257),PC(10),SR(30),FR(00)
Reads Fault Conditional Register. Return 2-digit hex.
Set Fault Enable Register using 2-digit hex.
Reads Fault Enable Register. Returns 2-digit hex.
Reads Fault Event Register. Returns 2-digit hex. Clears bits of Fault Event Register.
Reads Status Conditional Register. Returns 2-digit hex.
Sets Status Enable Register using 2-digit hex.
Reads Status Enable Register. Returns 2-digit hex.
Reads Status Event register. Returns 2-digit hex. Clears bits of Status Event register.
2
3
4
5
6
7
8
9
FLT?
FENA
FENA?
FEVE?
STAT?
SENA
SENA?
SEVE?
Table 7-4:
Table 7-5:
110
165
330
660
56