Section 5 Operating Parameters
5-1
2nd Ed Aug 2019
S-TEC 3100 Digital and Analog
Section 5 Operating Parameters
5.1.
ROLL AXIS LIMITS
Roll Attitude
: Greater 38° and not recovering (AP disconnects)
Roll Rate
: 10°/sec (AP disconnects)
5.2.
PITCH AXIS LIMITS
Pitch Attitude
: 22° and not recovering (AP disconnects)
Pitch Rate
: 4°/sec (AP disconnects)
5.3.
LEVEL MODE RECOVERY
Level mode is approved to recover from a maximum attitude of 51° pitch
and 76° roll.
5.4.
ENVELOPE SPEED LIMITS
The AP is approved to operate within the indicated airspeed limits as stated
within the relevant AFMS.