Trouble Inputs
Trouble inputs are used to monitor the status of the keypad and in most cases are not physically connected to
an external input. The following table details the trouble inputs that are configured in the system.
Trouble Input
Function
KPXXX:01
Module Tamper. Opens when the keypad is removed from the wall.
KPXXX:02
Reserved.
KPXXX:03
Keypad Panic. Keys 1 and 3 are pressed together generating a panic message.
KPXXX:04
Keypad Duress. A user code with the duress option enabled has entered a code on the
keypad.
KPXXX:05
Reserved.
KPXXX:06
Reserved.
KPXXX:07
Too Many Codes. Too many incorrect codes have been entered at the keypad and it
has been locked out for the set programmable lockout time.
KPXXX:08
Module Offline. The keypad has either been removed from the system or lost
communications.