SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual
Last Updated August 2018
24
Each of these inputs can be used for either the door function that is automatically assigned or as a general
purpose input. If used as general purpose inputs, make sure the inputs are not defined in the onboard reader
set up.
Input
Default Setting
Input 1
Door Contact
Input 2
REX Input
When connected, the REX Input can be programmed to operate regardless of the door contact state. The
REX input can also be programmed to recycle the door alarm time to prevent nuisance alarms when the door
is held open to permit longer entry.
Lock Output Connection
The Controller provides a connection for an electric strike lock using the integrated relay.
To use the lock output in conjunction with the onboard reader, the Lock output for the door associated with the
reader port must be configured to be the desired lock output on the Controller. This is not configured by
default.
Typical Lock Output Connection:
Z2
V-
Z1
NC
C
NO
ZONE 2
ZONE 1
R
ELA
Y
1
+
-
12VDC Electric
Locking Device
+
-
Power Supply