TECH TIPS
With the TCON, PCON, VCON and Right Motor Controller
connected to check the OHMS of the Can-Bus put the meter in
OHMS mode and check between the Green and the Yellow
wires on the Can-Bus connector located close to the TCON
location. The OHMS should read approximately 107.3 OHMS if
all connections are good. If this reading is good proceed to step
7
Step 6
To check the VCON (display module at the platform) with the
meter still connected at the TCON location unhook the Can-
Bus at the VCON. If the voltage goes to 2.6 and 2.1 the VCON
is defective.
If all readings are good proceed to step 6 and 7 to check the
OHMS readings.
Step 5