18
Genie S-80 & Genie S-85
Part No. 43650
Operator's Manual
Second Edition· Fifth Printing
FUNCTION TESTS
Test Auxiliary Controls
22 Turn the key switch to ground control and shut
the engine off.
23 Pull out the red Emergency Stop button to the
ON
position.
24 Simultaneously hold the auxiliary power switch
on and activate each boom function toggle
switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
At the Platform Controls
Test Emergency Stop
25 Turn the key switch to platform control and
restart the engine.
26 Push in the platform red Emergency Stop button
to the
OFF
position.
Result: The engine should turn off and all
functions should not operate.
27 Pull out the red Emergency Stop button and
restart the engine.
Test the Hydraulic Oil Return Filter
28 Move the engine idle select switch to high idel
(rabbit symbol).
29 Locate and check the hydraulic filter condition
indicator.
Result: The filter should
be operating with the
plunger in the green
area.
30 Move the engine idle
select switch to foot
switch activated high
idle (rabbit and foot
switch symbol).
Test the Service Horn
31 Push the horn button.
Result: The service horn should sound.
Test the Foot Switch
32 Push in the platform Emergency Stop button to
the
OFF
position.
33 Pull out the Emergency Stop button to
the
ON
position but do not start the engine.
34 Press down the foot switch and attempt to start
engine by moving the start toggle switch to
either side.
Result: The engine should not start.
35 Do not press down the foot switch and restart
engine.
36 Move the lift/drive select switch to the lift
position (if equipped).
37 Do not press down the foot switch. Then test
each machine function.
Result: The machine functions should not
operate.