10
10. Attach limit switch wires
.
•
Uncoil limit switch wires.
–
Place into channels located along top of rail.
–
Run wires back to power head through hole in top
of power head
(Fig. 1-12)
.
–
Use wire clips to hold wires in place
(Fig. 1-13)
.
•
Attach limit switch wires to terminals on power
head
(Fig. 1-14)
.
–
White wire ( OPEN ) to terminals #4 and #5.
–
Brown wire ( CLOSE ) to terminals #5 and #6.
•
Bundle extra wire and lay it on top of power head
(Fig. 1-14 inset)
.
9. Attach limit switches
.
2 switches included, CLOSE limit switch (brown
wire) and OPEN limit switch (white wire)
(Fig. 1-10)
.
•
Turn set screws (39) into threaded holes, just
enough so screw stays in place.
(Fig. 1-10)
.
•
Point arrow on top CLOSE limit switch toward
door end of rail.
–
Place CLOSE limit switch (Brown wire) on rail
about 12 from rail strap
(Fig. 1-11)
.
–
Gently tighten set screw enough to keep switch
from moving.
•
Point arrow on top OPEN limit switch toward
door end of rail.
–
Place OPEN limit switch (white wire) on rail
where chain attaches to carriage slide
. (Near
the power head.)
–
Gently tighten set screw enough to keep switch
from moving.
FIG. 1-10 Identify limit switches / insert set screws.
FIG. 1-11 Place limit switches.
FIG. 1-13 Wire clips.
FIG. 1-12 Run wire to power head.
FIG. 1-14 Attach wire at power head terminals.