Section 5 • Fault Codes
Part No. 227656
GR-20J • GR-26J
5 - 13
September 2016
FAULT CODE CHART
Error Source
Error Type
ID
Name
ID
Name
Condition
Solution
49
Pump shorted
The pump inputs of the
base board are short-
circuited.
It is an internal fault.
Replace the controller.
57
No CAN
message
The interface board has
not received the message
from CAN "N"
(1= CMD+TRAC
2=INTERFACE
5 = MIN_TRAC)
Check the BUSCAN
connection between the
modules. Otherwise, there is
an internal fault in a module
which causes a transmission
error, or there is excessive
noise on the BUSCAN line
which is interfering with the
signal.
60
High
temperatures
The power section of the
fuse has reached the
temperature limit: the
maximum current is
automatically reduced.
The alarm disappears as soon
as the cutout cools down. If this
does not happen, there is a
problem with the internal
temperature sensor.
65
Value of
angle sensor
incorrect
The value read by the
potentiometer is different
from the programmed
value.
Check that the angle sensor
potentiometer is functioning
correctly. Otherwise, check the
wiring.
02
Controller
logic
board
87
Time delay
The controller board asks
the base board to activate
the drive motors or the
pump. If they are not
activated after 400 ms, this
alarm is activated.
Check the software versions
installed on the interface and
logic board. This alarm may be
due to a software disparity.
Otherwise, there is an internal
fault.