Section 5 • Fault Codes
Part No. 227656
GR-20J • GR-26J
5 - 3
September 2016
Fault Code Chart
Error Source
Error Type
ID
Name
ID
Name
Condition
Solution
02
Logic fault #1
The base board is waiting
for the controller to
complete its internal test.
This alarm may appear from
time to time upon starting. Any
initialization delay can cause
this alarm to appear. If the alarm
appears too often or if it is
permanent, there is an internal
error. Check the current
software version or replace the
controller.
03
Valv. Drv. off
line
The internal device which
controls all the auxiliary
outputs has a problem
and is not communicating
correctly with the
microcontroller.
Replace the controller.
04
Output
mismatch
overcharge
This alarm is due to a
disparity between the
operating states detected
by the two computers. The
controller has asked the
base board to activate the
output for the drive or the
pump but the interface
does not identify a
command or an operating
state where the drive or
pump must be allowed.
Check whether the software
versions installed on the two
consoles are correct. If so, there
must be an internal fault.
05
EEPROM
There is a fault in the
management/verification
of the internal EEPROM.
It is an internal fault. Replace
the controller. The platform can
still function but the controller
will use default values for the
internal parameters.
06
Wrong RAM
memory
The algorithm used to
verify the main memory is
working with erroneous
data.
Try to break the contact. If the
alarm is still present, replace the
controller.
10
Flash check
Incorrect software
downloaded or the Flash
memory is corrupted.
Check the installed software
version or replace the controller.
01
Controller
interface
board
15
Analog input
There is a fault in the A/D
converter of the micro-
controller.
Replace the controller.