Section 5 • Fault Codes
Part No. 227656
GR-20J • GR-26J
5 - 5
September 2016
FAULT CODE CHART
Error
S
ource Error
Type
Condition
S
olution
ID Name
ID
Name
01
Controller
interface
board
50
Multi
selection
The electric brake is short-
circuited.
Several movements
activated simultaneously.
Check the conformity of the
control selectors.
51
Plat. double
required
The controller receives
several commands
simultaneously from the
platform controls circuit
board.
Check the wiring or change the
controller.
52
GND double
required
The controller receives
several commands
simultaneously from the
platform controls circuit
board.
Check the wiring or change the
controller.
53
Tilted
Tilt triggers audible
warning beep.
Check the conformity of the tilt
sensor and its connection or
change the controller.
54
Overload
HBT
Overload of HBT2 and
HBT1 signals Overload
incoherence.
Check the condition of the
overload sensors or change the
controller.
55
Overcharge Overload
fault.
Check the condition of the
overload sensors or change the
controller.
56
Battery low
Low battery voltage.
If the alarm is triggered when
the battery is fully charged,
change the controller.
57
No CAN
signal
The interface board has
not received the CAN
signal.
Check the BUSCAN connection
between the modules or change
the controller.
58
No alarm on
the console
There is a large disparity
between the hour counter
stored in the diagnostic
display and the hour
counter stored in the
controller. The maximum
acceptable difference is
10 hours. If it is greater,
this alarm will appear.
After two minutes, the hour
counter of the controller will
automatically find the diagnostic
display.
59
Temperature
of pump high
The temperature sensor of
the pump has detected a
high temperature.
The alarm should disappear as
soon as the pump motor cools
down. If this does not happen,
there is a problem with the
connection of terminal A16 or
the temperature sensor.