Section 4 • Repair Procedures
REV A
June 2007
Part No. 112657
GS-2668 RT • GS-3268 RT
4 - 75
14 Pull out the red Emergency Stop button to the
on position at the ground controls. Wait 3
seconds and start the engine.
Result: The alarm doesn't sound and the engine
will start and run. Proceed to step 15.
Result: The engine will not start and an alarm is
sounding. Repeat this procedure beginning with
step 12.
Note: The red Emergency Stop button must be
cycled after each quarter turn of the nut to allow
the platform overload system to reset.
Note: Wait a minimum of 3 seconds between each
quarter turn of the nut to allow the platform
overload system to reset.
15 Raise the platform until the position indicator
corresponds to the maximum load position of
the capacity indicator decal.
Tip-over hazard. Raising the
platform with maximum load
above the maximum load position,
as shown on the capacity indicator
decal on the side of the platform,
could result in the machine tipping
over, resulting in death or serious
injury. Do not raise the platform
above the maximum load position
of the capacity indicator decal.
Note: To perform this step, the lift relief valve will
need to be adjusted.
Note: Before raising the platform, applying a piece
of tape onto the underside of the platform, at a
point which corresponds to the maximum load
position of the capacity indicator decal, may help
complete this part of the procedure.
Result: The engine continues to run. Proceed to
step 16.
Result: The engine has stopped and an alarm is
sounding. Proceed to step 17.