Replace the Hydraulic Tank
Breather Cap -
Models with
Optional Hydraulic Oil
Genie requires that this procedure be performed
every 500 hours or six months, whichever comes
first.
The hydraulic tank is a vented-type tank. The
breather cap has an internal air filter that can
become clogged or, over time, can deteriorate. If
the breather cap is faulty or improperly installed,
impurities can enter the hydraulic system which
may cause component damage. Extremely dirty
conditions may require that the cap be inspected
more often.
1 Remove and discard the hydraulic tank breather
cap.
2 Install and new cap onto the tank.
C-4
Perform Engine Maintenance -
Diesel Models
Engine specifications require that this procedure
be performed every 500 hours.
Required maintenance procedures and additional
engine information is available in the
Kubota D1105 Operator's Manual
(Kubota part number 16622-89166) OR the
Kubota D905 Operator's Manual
(Kubota part number 16622-8916-5) OR the
Perkins 403D-11 User's Handbook
(Perkins part number SEBU8311-01) OR the
Perkins 403C-11 User's Handbook
(Perkins part number 100816460).
Kubota D1105 Operator's Manual
Genie part number
131379
Kubota D905 Operator's Manual
Genie part number
84240
Perkins 403D-11 User's Handbook
Genie part number
131661
Perkins 403C-11 User's Handbook
Genie part number
97360
Summary of Contents for GS-2668 RT
Page 4: ...June 2007 GS 2668 RT GS 3268 RT Part No 112657 iv This page intentionally left blank ...
Page 14: ...June 2007 GS 2668 RT GS 3268 RT Part No 112657 xiv This page intentionally left blank ...
Page 184: ... from serial number GS6805 44771 Part No 112657 Rev C2 Service Manual GS 2668 RT GS 3268 RT ...