November 2016
Service and Repair Manual
Platform Overload Components
Part No. 1272220GT
GS-2669 DC • GS-3369 DC • GS-4069 DC
91
11- 2 Plat form Ov erload R ec ov ery
11-2
Platform Overload Recovery
Message
If the ground controls LCD screen displays
OL:
PLATFORM OVERLOADED
, the emergency
lowering system has been used while the platform
was overloaded.
How to Clear the Platform
Overload Recovery Message
Note: This message shall be cleared by a person
trained and qualified on the troubleshooting and
repair of this machine.
Note: Use the following chart to identify the
description of each LCD screen control button used
in this procedure.
Escape
Scroll up
Scroll down
Enter
1
Turn the key switch to the ground controls
position and pull out the red Emergency Stop
button to the on position at the platform
controls.
2
Press and hold the ground control
scroll up
and
scroll down
buttons.
3
Pull out the red Emergency Stop button at the
ground controls.
Result: The ground control LCD display will
show the following.
4
Press the
scroll down
button.
Result: The ground control LCD display will
show the following.
5
Press the
enter
button.
Result: The ground control LCD display will
show the following.
6
Press the
enter
button.
Result: The ground control LCD display will
show the following.