Service and Repair Manual
November 2016
Fault Codes
112
GS-2669 DC • GS-3369 DC • GS-4069 DC
Part No. 1272220GT
Type "CXXX" Faults
Type "CXXX" Faults
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
C001
C001:GCON ECM
FAULT TYPE 1
GCON ECM CRC check error.
• Incorrect software file.
• GCON ECM internal failure.
All functions inhibited.
C004
C004:GCON ECM
FAULT TYPE 4
GCON ECM master switch error.
• Short circuit in the master switch circuit.
• GCON ECM.
All functions inhibited.
C005
C005:GCON ECM
FAULT TYPE 5
GCON ECM safety switch error.
• Short circuit in the safety switch circuit.
• GCON ECM.
All functions inhibited.
C006
C006:GCON ECM
FAULT TYPE 6
GCON input redundancy error.
• Input conditioning circuit failure.
• GCON ECM.
All functions inhibited.
C007
C007:GCON ECM
FAULT TYPE 7
GCON ECM inter-processor
communication error.
• Incorrectly programmed device.
• Error in loading software on device.
• GCON ECM.
All functions inhibited.
C008
C008:GCON ECM
FAULT TYPE 8
GCON ECM temperature sensor
error.
• GCON ECM internal failure.
• GCON ECM.
All functions operate.
C009
C009:GCON ECM
FAULT TYPE 9
GCON fault type 9.
• Contact Genie support.
C010
C010:SECONDARY
NOT PROGRAMMED
Secondary not programmed.
• Reinstall software
• Contact Genie support.
All functions inhibited.
C021
C021:PCON NOT
DETECTED
Communication failure between
GCON and PCON.
• CAN communication failure.
• CAN communication harness.
• PCON disconnected.
• GCON or PCON ECM.
All functions inhibited.
C023
C023:MACHINE
MODEL FAULT
Discrepancy between model
detected and model programmed.
• Incorrect machine model programmed.
• GCON or PCON ECM.
All functions inhibited.
C025
C025:SYSTEMFAULT
PLAT OVLD:NOCAL
Platform overload system not
calibrated.
• Platform overload system not calibrated.
• GCON or PCON ECM.
All functions inhibited.
C028
C028:SERVICE
OVERRIDE MODE ON
Machine is in service override mode. • Machine programmed for use in service override mode.
All functions inhibited
except for down function
and up function.
Platform can be elevated
only once with the
maximum elevate time of
XX seconds.
Elevate time XX depends
on machine model.
C029
C029:SYSTEMFAULT
OUTRIGGER:NoCal
Outrigger fault, not calibrated.
• Calibrate outriggers
• Contact Genie support.
All functions operate. Will
not lift above the down
limit switches.
C030
C030:DCON RR ECM
FAULT TYPE 01
Hardware failure of the right rear
drive controller.
• Right rear DCON ECM.
Performance reduced or
all functions inhibited.
C031
C031:DCON LR ECM
FAULT TYPE 01
Hardware failure of the left rear drive
controller.
• Left rear DCON ECM.
Performance reduced or
all functions inhibited.
C032
C032:DCON RR ECM
FAULT TYPE 02
Setup initialization failure of the right
rear drive controller at system
startup.
• Drive input active at system startup.
• Faulty drive joystick.
• Incorrect software.D14
• Right rear DCON ECM.
Performance reduced or
drive inhibited or all
functions inhibited.
C033
C033:DCON LR ECM
FAULT TYPE 02
Setup initialization failure of the left
rear drive controller at system
startup.
• Drive input active at system startup.
• Faulty drive joystick.
• Incorrect software.D14
• Left rear DCON ECM.
Performance reduced or
drive inhibited or all
functions inhibited.