Service and Repair Manual
November 2016
Platform Controls
10
GS-2669 DC • GS-3369 DC • GS-4069 DC
Part No. 1272220GT
Pl atform Contro ls
Platform controls
The platform controls are used to operate the
machine from the platform.
Activating a function button sends a signal to the
Electronic Control Module (ECM). When the ECM
is in the function mode, the platform controls are
used to operate the various machine functions.
The platform controls consist of an Emergency
Stop button, electronic circuit board, proportional
control handle, drive/steer enable switch, alarm,
function buttons and LED display.
For further information or assistance, contact
Genie Product support.
1 red Emergency Stop button P2
2 platform controls circuit board U3
3 proportional control handle and drive/steer
enable switch JC9
4 alarm H1
Operational Indicator Codes (OIC)
These codes are generated by the electrical
system to indicate machine operating status.
During normal operation a code will appear in the
platform controls LED readout if a condition such
as off-level, overload cutout, chassis mode
operation or pothole guards stuck occurs.These
codes are not indicators of a device malfunction in
the electrical system.
If the platform controls LED readout displays an
operational indicator code such as LL, the fault
condition must be repaired or removed before
resuming machine operation. Push in and pull out
the red Emergency Stop button to reset the
system.
Platform Controls LED Readout
Code
Condition
LL
Off-Level
OL
Platform Overload (CE and Australia)
CH
Chassis Mode Operation
nd
No Drive (option)
F053
DCON RR Thermal Protection
F054
DCON LR Thermal Protection
Ld
Lifting Disabled (option)
St
Engine Start Delay
Note: A code and a description of a code can also