Section 4 • Repair Procedures
November 2014
Part No. 229753
GS-2669 RT • GS-3369 RT • GS-4069 RT
4 - 39
4 Use the yellow platform down arrow to scroll to
select options.
Result:
SELECT
OPTIONS
is showing in the
diagnostic display window. The ECM is now in
programming mode.
5 Press the lift function enable button.
Result:
DESCENT
DELAY
is showing in the
diagnostic display window. Press the lift
function enable button to activate or deactivate
the descent delay option.
Note: For CE and AS models, the descent delay
option should be activated or in the
ON
position.
6 Use the yellow platform down arrow to scroll to
motion alarm.
Result:
MOTION
ALARM
is showing in the
diagnostic display window.
7 Press the lift function enable button to activate
or deactivate the motion alarm option OR use
the yellow platform down arrow to scroll to
motion beacon.
Result:
MOTION
BEACON
is showing in the
diagnostic display window.
8 Press the lift function enable button to activate
or deactivate the motion beacon option.
Note: For this option to function correctly, the
machine must be equipped with flashing beacons.
Note: If the machine is not equipped with flashing
beacons and this option is set to on, the ECU will
display a 4021 fault code.
9
Models with platform overload (option):
Use
the yellow platform down arrow to scroll to
overload.
Result:
OVERLOAD
ON
is showing in the diagnostic
display window.
Result:
OVERLOAD
OFF
is showing in the diagnostic
display window. Press the lift function enable
button to activate the overload option.
Note: For CE and AS models, the overload option
should be activated or in the
ON
position.
10 Use the yellow platform down arrow to scroll to
beacons option.
Result:
BEACONS
ON
is showing in the diagnostic
display window. Press the lift function enable
button to activate or deactivate the beacons
option.
Note: For this option to function, the machine must
be equipped with flashing beacons and the software
set to
BEACONS
ON
.
Note: If the machine is not equipped with flashing
beacons and this option is set to on, the ECU will
display a 4021 fault code.
11 Use the yellow platform down arrow to scroll to
generator option.
Result:
GENERATOR
ON
is showing in the diagnostic
display window. Press the lift function enable
button to activate or deactivate the generator
option.
Note: For this option to function correctly, the
machine must be equipped with the required
generator components and the software set to
GENERATOR
ON
.
GROUND CONTROLS
Summary of Contents for GS-2669 RT
Page 169: ...Section 6 Schematics November2014 6 9 Control Panel Circuit Diagram 6 10 ...
Page 235: ...Section 6 Schematics November2014 6 75 6 76 Electrical Schematic GS 4069 RT Gas LPG Models AS ...
Page 238: ...November2014 Section 6 Schematics 6 78 Electrical Schematic GS 4069 RT Gas LPG Models AS 6 77 ...
Page 243: ...Section 6 Schematics November2014 6 83 Electrical Schematic GS 4069 RT Diesel Models AS 6 82 ...
Page 246: ...November2014 Section 6 Schematics 6 86 Electrical Schematic GS 4069 RT Diesel Models AS 6 85 ...
Page 251: ...Section 6 Schematics November2014 6 91 Electrical Schematic GS 4069 RT Gas LPG Models CE 6 92 ...
Page 254: ...November2014 Section 6 Schematics 6 94 Electrical Schematic GS 4069 RT Gas LPG Models CE 6 93 ...
Page 259: ...Section 6 Schematics November2014 6 99 6 100 Electrical Schematic GS 4069 RT Diesel Models CE ...
Page 267: ...Section 6 Schematics November2014 6 107 Hydraulic Schematic GS 2669 RT and GS 3369 RT 6 108 ...
Page 270: ...November2014 Section 6 Schematics 6 110 Hydraulic Schematic GS 4069 RT 6 109 ...