August 2018
Part No. 57.4400.9220GT
GTH-2506 GTH-3007
6-29
Section 6 Fault Codes
SPN
FMI Short Text Detail
2621
12
Flush valve burner (EPV DPF-System); powerstage over temperature
2659
0
Physical range check high for EGR exhaust gas mass flow
2659
1
Physical range check low for EGR exhaust gas mass flow
2659
2
Exhaust gas recirculation AGS sensor; plausibility error
2659
2
AGS sensor temperature exhaust gas mass flow; plausibility error
2659
12
Exhaust gas recirculation; AGS sensor has "burn off" not performed
2797
4
Injector diagnostics; timeout error of short circuit to ground measurement cyl. Bank 0
2798
4
Injector diagnostics; timeout error of short circuit to ground measurement cyl. Bank 1
2798
4
Injector diagnostics; short circuit to ground monitoring Test in Cyl. Bank 0
2798
4
Injector diagnostics; short circuit to ground monitoring Test in Cyl. Bank 1
3031
0
AdBlue-Tank temperature: maximum exceeded
3031
1
DEF-Tank temperature: below minimum
3031
3
Sensor error urea tank temperature; short circuit to battery
3031
4
Sensor error urea tank temperature; short circuit to ground
3224
1
Nox sensor upstream of SCR Catalysator; low signal not plausible
3224
2
DLC Error of CAN-Receive-Frame AT1IG1 NOX Sensor (SCR-system upstream cat; DPF-system downstream cat); length of
frame incorrect
3224
2
DLC Error of CAN-Receive-Frame AT1IG1Vol NOX Sensor (SCR-system upstream cat; DPF-system downstream cat); length
of frame incorrect
3224
9
Timeout Error of CAN-Receive-Frame AT1IG1; NOX sensor upstream
3224
9
Timeout Error of CAN-Receive-Frame AT1IG1Vol; NOX sensor (SCR-system upstream cat; DPF-system downstream cat)
3234
2
DLC Error of CAN-Receive-Frame AT1O1Vol NOX Sensor (SCR-system downstream cat; DPF-system downstream cat);
length of frame incorrect
3234
9
Timeout Error of CAN-Receive-Frame AT1OG1; NOX sensor (SCR-system downstream cat; DPF-system downstream cat)
3234
9
Timeout Error of CAN-Receive-Frame AT1OG1Vol; NOX sensor (SCR-system downstream cat; DPF-system downstream
cat)
3234
11
Nox Sensor downstream of SCR Catalysator; plausibility error "stuk in range"
3241
0
Sensor SCR catalyst upstream temperature too high; plausibility error
3241
1
Sensor SCR catalyst upstream temperature too low; plausibility error
3248
0
Physical range check high for exhaust gas temperature particulate filter downstream
3248
0
Physical range check high for exhaust gas temperature particulate filter downstream; shut off regeneration
3248
0
Physical range check high for exhaust gas temperature particulate filter downstream; warning
3248
1
Physical range check low for exhaust gas temperature particulate filter downstream
3248
1
Physikal range check low for exhaust gas temperature particulate filter downstream; shut off regeneration
3248
1
Physical range check low for exhaust gas temperature particulate filter downstream; warning
FAULT CODES