Page
C - 17
Document 57.0008.7200 - 05/2007
Handler with telescopic boom
GTH-3512
OPERATING INSTRUCTIONS
■
C-3.4.2
Emergency stop
The operated functions can be stopped at any time by
pressing the emergency stop button
씍
.
By pressing this button, the engine of the machine is
shut down.
Before restarting the machine, it is necessary to reset
the pushbutton by rotating it clockwise.
CAUTION
Before restarting the machine, find and rectify the
faults that caused the emergency
■
C-3.4.3 Disabling the moment limiting system
The load limiter can be deactivated operating the key-
selector placed under the protection cover
씎
.
DANGER
WORKING WITH THE MOMENT LIMITING SYSTEM
CUT OUT CAN RESULT IN A MACHINE
OVERTURNING AND IN SERIOUS INJURY.
씎