FAULT CODES
SPN
FMI Short Text Detail
523606
9
Timeout Error of CAN-Receive-Frame TSC1AR; Retarder
898
9
Timeout Error of CAN-Receive-Frame TSC1TE; Setpoint
520
9
Timeout Error of CAN-Receive-Frame TSC1TR; Setpoint
523867
12
Timeout Error of CAN-Transmit-Frame UAA1 on CAN 2; Burner Air Pump Control
523982
0
Powerstage diagnosis disabled; high battery voltage
523982
1
Powerstage diagnosis disabled; low battery voltage
630
12
Access error EEPROM memory (delete)
630
12
Access error EEPROM memory (read)
630
12
Access error EEPROM memory (write)
411
4
Physical range check low for EGR differential pressure
523612
12
Internal software error ECU; injection cut off
190
0
Engine speed above warning threshold (FOC-Level 1)
190
11
Engine speed above warning threshold (FOC-Level 2)
190
14
Engine speed above warning threshold (Overrun Mode)
108
3
Sensor error ambient air pressure; signal range check high
108
4
Sensor error ambient air pressure; signal range check low
171
3
Sensor error environment temperature; signal range check high
171
4
Sensor error environment temperature; signal range check low
190
8
Sensor camshaft speed; disturbed signal
190
12
Sensor camshaft speed; no signal
190
2
Offset angle between crank-and camshaft sensor is too large
190
8
Sensor crankshaft speed; disturbed signal
190
12
Sensor crankshaft speed; no signal
703
5
Engine running lamp; open load
703
12
Engine running lamp; powerstage over temperature
703
3
Engine running lamp; short circuit to battery
703
4
Engine running lamp; short circuit to ground
975
5
Digital fan control; open load
975
12
Digital fan control; powerstage over temperature
975
3
Digital fan control; short circuit to battery
975
4
Digital fan control; short circuit to ground
975
5
Fan actuator (PWM output); open load
975
12
Fan actuator (PWM output); powerstage over temperature
975
3
Fan actuator (PWM output); short circuit to battery