4-10
GTH-5519
Part No. 1272852
September 2016
Section 4 • Fault Codes
FAULT CODES
SPN
FMI Short Text Detail
100
1
Low oil pressure; shut off threshold exceeded
175
2
Sensor oil temperature; plausibility error
175
2
Sensor oil temperature; plausibility error oil temperature too high
175
0
Physical range check high for oil temperature
175
1
Physical range check low for oil temperature
175
3
Sensor error oil temperature; signal range check high
175
4
Sensor error oil temperature; signal range check low
175
0
High oil temperature; warning threshold exceeded
175
0
High oil temperature; shut off threshold exceeded
1237
2
Override switch; plausibility error
107
3
Sensor error airfilter differential pressure; short circuit to battery
107
4
Sensor error airfilter differential pressure; short circuit to ground
107
0
High air filter differential pressure; warning threshold exceeded
523919
2
Sensor airpump pressure; plausibility error
523919
0
Physical range check high for airpump pressure; shut off regeneration
523919
1
Physical range check low for airpump pressure; shut off regeneration
523919
3
Sensor error airpump pressure; signal range check high
523919
4
Sensor error airpump pressure; signal range check low
523920
2
Sensor exhaustgas back pressure; plausibility error
523920
0
Physical range check high for exhaustgas back pressure burner; shut off regeneration
523920
1
Physical range check low for exhaustgas back pressure burner; shut off regeneration
523920
3
Sensor error exhaustgas back pressure burner; signal range check high
523920
4
Sensor error exhaustgas back pressure burner; signal range check low
102
3
Sensor error charged air pressure; signal range check high
102
4
Sensor error charged air pressure; signal range check low
411
0
Physical range check high for differential pressure Venturiunit (EGR)
411
1
Physical range check low for differential pressure Venturiunit (EGR)
411
3
Sensor error differential pressure Venturiunit (EGR); signal range check high
411
4
Sensor error differential pressure Venturiunit (EGR); signal range check low
524025
14
Particulate filter; regeneration not succesful
3253
2
Sensor differential pressure (DPF); plausibility error regarding signal offset
3251
0
Physical range check high for differential pressure (DPF); shut off regeneration
3251
1
Physical range check low for differential pressure (DPF); shut off regeneration
3253
3
Sensor error differential pressure (DPF); signal range check high